No. 52005
AV-27F703
AV-27F713
AV-27F803
25
Item
Measuring
instrument
Test point
Adjustment part
Description
*
V. HEIGHT / V. POSITION adjustment s hould be fi nished.
*
H. SIZE, H. POSI and SIDE PIN adjustment s hould be
finished. (Regular size(4:3)).
H. POSITION
H. SIZE &
SIDE PIN
adjustment
(16:9)
Signal
generator
D04:H.POSI+-
D16:H. SIZE+-
D20:EW CR T+-
D22:EW CR B+-
D24:EW PARA+-
1. Receive the cr oss-hatc h signal.
2. Select
16:9
as pect mode with remote c ontr ol unit.
3. Enter the SERVICE MENU.
4. Confirm both sides of cross-hatch to be the adjustment value
90%
.
5. If it not c orrect, adjust to be value
90%
at the
D16:H. SIZE
+-
and
D04:H.POSI+-
.
6. Confirm the vertical 2
nd
line from lift and right to be straight.
7. If it is not str aight, adjust to be straight at
D24:EW PARA+-
,
D20:EW CR T+-
and
D22:EW CR B+-
.
(NOTE)
*
Review the adjustment of 16:9 mode again when you c hange
the SIDE PIN adjustment value of r egular (4:3) mode.
*
Main pictur e’s V. HEIGHT, V. POSI, H. SIZE, H. POSI. Shoul d
be fi nished.
*
Set the VIDEO STATUS to STANDARD.
PIP DISPLAY
POSITION
adjustment
(AV-27F 803
/S
)
Signal
generator
PIP11:L POSI.
PIP12:R POSI.
PIP13:UPR POSI.
PIP14:LW R POSI.
1. Receive a blac k -and- white signal (color off)
2. Enter the SERVICE MENU.
3. Select
the
5:PIP(PIP)
fr om SERVIC E MENU.
4. Set
the
initial setting value of the
PIP13:UPR POSI.
with the
( / ) key of the remote control unit.
5. Adjust the
PIP13:UPR POSI.
so that he position of the PIP
screen edge of upper will be at
X1 as sho wn.
6. Adjust the corresponding modes of
PIP14
,
PIP11
,
PIP12
with
the s ame steps as 3
~
5 above.
No.
Setting item
Variable
range
Setting
value
D04
H. POSI+-
-128
~
+127
00
D16
H. SIZE+-
-128
~
+127
00
D20
EW CR T+-
-128
~
+127
00
D22
EW CR B+-
-128
~
+127
00
D24
EW PARA+-
-128
~
+127
00
Picture
size
100%
Picture size 100%
Screen
size
90.0%
Screen size 90.0%
(V)
(H)
Setting position
Item
No.
Setting
item
Variable
range
setting
value
POSI.
(%)
PIP13 UPR POSI
0
~
127
12
X1
80
PIP14 LW R POSI
0
~
127
11
X2
80
PIP11
L. POSI
0
~
255
22
Y1
80
PIP12
R. POSI
0
~
255
15
Y2
80
Y1
(LEFT POSI.)
Y2
(RIGHT POSI.)
X1
(UPPER POSI.)
X2
(LOWER POSI.)
PIP screen