No. 51940
AV-27D303
AV-27D203
26
Item
Measuring
instrument
Test point
Ad justment part
Description
[ Method of adjustment without measuring instrument ]
SUB TINT
adjustment
Signal
generator
Remote
control unit
S04. TINT
1. Receive the broadcast.
2. Select
S04. TINT
of the V/C MODE.
3. Set the initial s etting value of the
S04. TINT
with the
MENU / (VOL-/+) key .
4. If the tint is not the bes t with the initial setting value, make fine
adjustment of the
S04. TINT
until you get the optimum tint.
[ Method of adjustment using measuring instrument ]
Signal
generator
Oscilloscope
Remote
control unit
TP-B
TP-E(
#
#
#
#
)
[CRT
SOCKET
PWB]
S04. TINT
1. Input the full field c olor bar signal (75% white).
2. Select
S04. TINT
of the V/C MODE.
3. Set the initial s etting value of the
S04. TINT
with the
MENU / (VOL-/+) key.
4. Connect the osc illosc ope between
TP-B
and
TP-E
.
5. Adjust TINT and bring the value of
(B)
in the illustration to the
voltage shown in the table bellow.
(B)
W
Cy G
Mg
B
R
Y
0V
(
-
)
(
+
)
No
Setting item
Variable
range
Initial setting
value
S04
TINT
0
~
127
60
W-Mg
Models
Voltage
AV-27D303/S
+20V
AV-27D203/S
+20V
AV-27D303/R
+25V
AV-27D203/R
+25V