(No.YA445)1-23
SIDE PIN
Signal
generator
Remote
control unit
[4. DEF]
7. EW-PIN
PAL SIDE PIN
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<7. EW-PIN>
.
(4) Set the initial setting value of
<7. EW-PIN>
.
(5) Adjust
<7. EW-PIN>
so that the first vertical lines at
the left and right edges on the screen are straight.
(6) Press the
[OK]
key to memorize the set values.
NTSC SIDE PIN
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL SIDE PIN.
TRAPEZIUM
Signal
generator
Remote
control unit
[4.DEF]
6. TRAPEZ
PAL TRAPEZIUM
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<6. TRAPEZ>
.
(4) Set the initial setting value of
6. TRAPEZ
.
(5) Adjust
<6. TRAPEZ>
so that the vertical lines at the
left and right edges on the screen are in parallel.
(6) Press the
[OK]
key to memorize the set values.
NTSC TRAPEZIUM
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL TRAPEZIUM.
V.LINEARITY
Signal
generator
Remote
control unit
[4. DEF]
12. V-S. CR
13. V-LIN
PAL V. LINEARITY
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<12. V-S.CR>
.
(4) Set the initial setting value of
<12. V-S. CR>
.
(5) Select
<13. V-LIN>
.
(6) Set the initial setting value of
<13. V-LIN>
.
(7) Adjust
<12. V-S. CR>
and
<13. V-LIN>
so that the
spaces of each line on TOP, CENTRE and
BOTTOM become uniform.
(8) Press the
[OK]
key to memorize the set values.
NTSC V. LINEARITY
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 8 as in PAL V-S. CR.
Item
Measuring
instrument
Test point
Adjustment part
Description
Straight
Parallel
Top
Centre
Bottom