No. 52055
AV-21BF11ENS
AV-21BF11EES
AV-21BF11EPS
AV-21BF11EJS
15
ADJUSTMENTS
■
■
■
■
SCREEN ADJUSTMENT
Item
Measuring
instrument
Test point
Ad justment part
Description
SCREEN
adjustment
Remote
control unit
SCREEN VR
[On the FBT]
1. Enter SERVICE MENU.
2. Press YELLOW key to disable vertic al s can.
3. Adjust SCREEN VR. on the FBT as thin as possible.
4. Press YELLOW k ey again to enable vertical sc an.
5. Press MENU key to leav e service menu.
■
OSD HORIZONTAL POSITION ADJUSTMENT
Item
Measuring
instrument
Test point
Ad justment part
Description
HORIZONTAL
POSITION OF
OSD
adjustment
Remote
control unit
OSD
1. Enter SERVICE MENU.
2. Select OSD with FUNCTION ( / ) key
3. Adjust the OSD horizontal pos ition with the FUNCTION ( / )
key, whic h shifts the reference bar on the bottom of the
SERVICE MENU horizontally, s o that the OSD is positioned on
the screen c enter. (
X
=
X’
)
■
■
■
■
IF ADJUSTMENT
Item
Measuring
instrument
Test point
Ad justment part
Description
IF adjustment
Remote
control unit
IF 1
IF 2
IF 3
IF 4
1. Enter SERVICE MENU.
2. Select IF 1 with FUNCTION ( / ) key
3. Press BLUE key during IF 1 is highlighted, IF 1 and IF 2 values
are adjusted automatic ally by software.
4. If the standard is L-prime, IF 3 and IF 4 values are adjustment
automatic ally when BLUE key is press ed during IF 1 is
highlighted.
Reference bar
Screen size
SERVICE MENU SCREEN
X
X’