1-24 (No.YA415)
4.8.6 VSM PRESET SETTING
[4.VSM PRESET]
Item
Measuring
instrument
Test point
Adjustment part
Description
VSM PRESET
Remote
control unit
[4. VSM PRESET]
TINT
COLOUR
BRIGHT
CONT.
SHARP
(1) Select 4. VSM PRESET from the SERVICE MENU.
(2) Set the PICTURE MODE to BRIGHT.
(3) Select
< TINT >
.
(4) Set the initial setting value of
< TINT >
as shown in
the below table.
(5) Select
< COLOUR >
to
< SHARP >
in turn, and set
the values.
(6) Respectively select the
"SOFT"
and
"STANDARD"
.
Make similar adjustment as same step as above.
BRIGHT
/ : SELECT
- / + : OPREATE DISP : EXIT
TINT
**
COLOUR **
BRIGHT **
CONT.
**
SHARP **
Setting
item
Variable
range
Initial setting value
BRIGHT
STANDARD
SOFT
TINT 0
-
30
15
15
15
COLOUR 0
-
30
15
15
15
BRIGHT 0
-
30
15
15
15
CONT. 0
-
30
30
15
11
SHARP 0
-
30
15
15
12