![JVC AV-14F71/VT Service Manual Download Page 26](http://html.mh-extra.com/html/jvc/av-14f71-vt/av-14f71-vt_service-manual_181658026.webp)
No. 51918
AV-14F71
26
Item
Measuring
instrument
Test point
Adjustment part
Description
●
●
●
●
When the vertical linearity has been deteriorated
remarkably, perform the following steps.
13. Input a cross-hatch signal.
14. Select
4. VER. LIN.
with the MENU
▼
/
▲
key.
15. Set the initial setting value of
4. VER LIN.
with the MENU - / +
key.
16. Select
5. VER. SCURVE
with the MENU
▼
/
▲
key.
17. Set the initial setting value of
5. VER. SCURVE
with the
MENU - / + key.
18. Adjust
4. VER. LIN.
and
5. VER. SCURVE
so that the spaces
of each line as shown in Fig.3 on
TOP
,
CENTER
and
BOTTOM
become uniform.
Adjustment
of VER. LIN.
& VER.
SCURVE
Signal
generator
Remote
control unit
4. VER. LIN.
5. VER. SCURVE
Make sure that the adjustment is properly done on the screen of
60Hz mode.
[NOTE]
"
Adjust to make both 50Hz & 60Hz are the same v. size and
fine straight line.
"
When adjust again, adjust 50Hz mode first.
"
When adjust in 60Hz mode, only 60Hz mode is adjust.
TOP
CENTER
BOTTOM
Fig.3