No.52021
AV-14F13
AV-14F33
24
Item
Measuring
instrument
Test point
Adjustment item
Description
[Method of adjustment using measuring instrument]
(PAL-M COLOR)
3. COL. PALM
1. Receive a PAL-M full field color bar signal (75% white).
2. Select the sub menu screen PICTURE from the SERVICE
MENU.
3. Select 3. COL. PALM with the MENU / key , and confirm
its initial setting value.
4. Connect the oscilloscope between TP-47B and TP-E.
1. Adjust 3. COL. PALM
to set the value
(A)
in the figure to
+7V
(W & B)
, with the MENU
-
/
+
key
(PAL-N COLOR)
4. COL. PALN
1. Receive a PAL-N full field color bar signal (75% white).
2. In the sub menu screen PICTURE, select 4. COL. PALN
with
the MENU / key, and confirm its initial setting value.
3. Connect the oscilloscope between TP-47B and TP-E.
4. Adjust 4. COL. PALN to set the value
(A)
in the figure to
+18V(W & B)
, with the MENU
-
/
+
key.
(NTSC COLOR)
Adjustment
of SUB
COLOR-
Ⅱ
Ⅱ
Ⅱ
Ⅱ
"
Signal
generator
"
Oscillo-
scope
"
Remote
control
unit
TP-47B
TP-E(
#
#
#
#
)
[ CRT
SOCKET
PWB ]
5. COL. NTSC
1. Receive a NTSC full field color bar signal (75% white).
2. In the sub menu screen PICTURE, select 5. COL. NTSC with
the MENU / key, and confirm its initial setting value.
3. Connect the oscilloscope between TP-47B and TP-E.
4. Adjust 5. COL. NTSC to set the value
(A)
in the figure to
+22V(W & B)
, with the MENU
-
/
+
key.
[Method of adjustment using measuring instrument]
Adjustment
of
SUB TINT-
Ⅱ
Ⅱ
Ⅱ
Ⅱ
"
Signal
generator
"
Oscillo-
scope
Remote
control
unit
TP-47B
TP-E(
#
#
#
#
)
[ CRT
SOCKET
PWB ]
6.TINT
1. Receive a NTSC 3.58 color bar signal (full field color bar
75%white).
2. Select the sub menu screen PICTURE from the SERVICE
MENU.
3. Select 6. TINT with the MENU / key, and confirm its initial
setting value.
4. Connect the oscilloscope betweenTP-47B and TP-E.
5. Adjust
6.
TINT
to set the value
(B)
in the figure to
+14V(W &
Mg)
, with the MENU
-
/
+
key.
W
Y
Cy
G
Mg
R
B
(A)
0V
( )
(+)
W
Y
Cy
G
Mg
R
B
(B)
0V
( )
(+)