JA95-R03 Audio Controller - Remote Mount - One Transceiver
Installation and Operating Manual
Rev
B
Page 11
2.5.3.6
Alerts
WARNING
:
The internal audio alert is intended only to supplement, NOT replace, airframe alerts such
as ‘low rotor RPM’, ‘engine out’ or ‘decision height alerting’. The alert audio feature is intended for
use as a secondary alerting system where another device provides the primary annunciation.
Audio Files
The JA95-R03 has a standard audio signal for the alert, and the audio file window allows this signal to be
customized with other recordings during the configuration process. The default Alert signal loaded into the unit at
the factory is JA95-R03 Wav File (Sine 1000Hz 10 sec) Rev A.WAV
Saving new Audio Files
2.5.3.7
Audio Muting (During Transmit)
When the Mute RX Audio check box is checked the
Receive Audio is muted during transmit (
Default checked
)
When the Mute ICS Audio check box is checked the ICS
Audio is muted during transmit (
Default checked
)
When the Mute Alert Audio check box is checked the Alert
Audio is muted during transmit (
Default not checked
)
The level of the Alert Audio signal is adjustable from 0 to -40 dB of the
rated phone level. (
Default -12 dB
)
If a new audio file is selected, it may be played using the arrow
to the right of the Message line.
It may be uploaded to the JA95-R03 using the 'Program' menu
and selecting 'Program JA95-R03 Messages…'.
Note that this pane will have different content if a JA95-R03 is