2, The operating instructions
Item
Introduction
“OUT”
This item can control the output status. Parameters will be
saved when set to OFF.Shutdown require relay coordination
“NCP”
This item can set Negative over-current protection.Press
“OK”can change the value, The function will be turned off
when set to 0.
(
The protection function requires the
cooperation of the relay
)
“OCP”
This item can set Posative over-current protection.Press
“OK”can change the value, The function will be turned off
when set to 0.
(
The protection function requires the
cooperation of the relay
)
“LVP”
This item can set low-voltage protection.Press “OK”can
change the value, The function will be turned off when set to
0.
(
The protection function requires the cooperation of the
relay
)
“OVP”
This item can set over-voltage protection.Press “OK”can
change the value, The function will be turned off when set to
0.
(
The protection function requires the cooperation of the
relay
)
“CLR”
This item can clear AH
、
WH and time value immediately
,
Real-time battery capacity will be set to 100%.
“BAT”
This item can set the total battery capacity and real-time
battery capacity.
“SET”
This function can set some configurtions of the instrument.
“ADR”
This item can set the Communication address.
“LNG”
This item can set the communication address.
“FCH”
This item can set the communication channel.
“BRI”
This item can set the display brightness.
Note: Leave the cursor at the "ADR" position and long press "DOWN"
key for 3 seconds to switch to the "LNG" option.