JUNO Optim FreedomView FVSD312 Manual Download Page 1

1

FreedomView

®

 SD LED Fiberscope 

Inspection Kits 

Part No. 0063251 

FVSD320 

Part No. 0063252 

FVSD340 

Part No. 006307 

FVSD312 

Part No. 0062971 

FVSD420 

Part No. 0062972 

FVSD440 

Distributed by:

 ABQ Industrial LP USA

Tel: 

+1 (281) 516-9292 / (888) 275-5772  

eFax:

 +1 (866) 234-0451

 

Web: 

http

s

://www.abqindustrial.net  

E-mail: 

[email protected]

Summary of Contents for Optim FreedomView FVSD312

Page 1: ...3251 FVSD320 Part No 0063252 FVSD340 Part No 006307 FVSD312 Part No 0062971 FVSD420 Part No 0062972 FVSD440 Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web...

Page 2: ...SD LED Fiberscope 6 C Internal LED Light Source 6 D Adjusting the Light Intensity Control 6 E Operating Temperature 6 F Immersion of Components 6 G Cleaning 7 Lithium Ion Battery and Battery Charger 7...

Page 3: ...ns This fiber optic viewing instrument is constructed of high quality durable materials and is designed for simplified integrations with complimentary components Read this manual thoroughly to familia...

Page 4: ...se until the fiber pattern is in clear focus Diopter Markings If using a video camera still photography system or teaching attachment the white dot on the Control Body must be aligned with the white d...

Page 5: ...any type 6 The high intensity light at the tip of the scope is extremely bright To minimize the risk of injury avoid direct viewing of the light When illumination is not required even for short inter...

Page 6: ...and off indicating it is time to recharge the battery Two batteries are included in the FreedomView SD LED Fiberscope Kit Additional batteries are available D Adjusting the Light Intensity Turn on the...

Page 7: ...Lithium ion battery and provides approximately 40 minutes of continuous operation when a new battery is fully charged When the battery is drained the light will flicker on and off indicating it is ti...

Page 8: ...e handle over so the battery drops out into your other hand Please take care not to let the battery fall to the floor or onto a hard object which could damage the battery To insert a new battery align...

Page 9: ...transport When the Fiberscope is not in use put it into the foam insert with the shaft below the top of the insert Always store and transport Fiberscope components in the carrying case If the Freedom...

Page 10: ...n lens Refer to Section 3G Fluid leakage into the internal shaft Return to OPTIM for service Loose Lenses Return to OPTIM for service INSUFFICIENT ARTICULATION POSSIBLE CAUSE SOLUTION Stretched contro...

Page 11: ...VSD440 Outer Diameter 4 0mm 155 inches Working Lengths 51cm 20 inches 102cm 40 inches Shaft Covering Tungsten Articulation 2 Way 120o Up Down Depth of Field 10 100mm 24 4 0 inches FreedomView SD LED F...

Page 12: ...pe Models FVSD320 3 2mm x 20 0063251 FVSD340 3 2mm x 40 0063252 FVSD312 3 6mm x 12 006307 FVSD420 4 0mm x 20 0062971 FVSD440 4 0mm x 40 0062972 Battery Charger Cradle 006177 US AC Power Supply 007002...

Page 13: ...en be returned to the address below for repair or replacement Returning Goods to OPTIM Incorporated Ship the fiberscope in the carrying case and within a corrugated box to prevent damage during shipme...

Page 14: ...re the responsibility of the customer All non warranty repairs will be warranted to be free from defects in materials and workmanship for a period of ninety 90 days from the date of the invoice Accide...

Page 15: ...r Light intensity symbol Moving the light intensity lever towards the wider end of this symbol increases the light intensity Moving towards the narrower end decreases the light Light intensity lever S...