- INSTALLATION INSTRUCTIONS
1 - GENERAL INFORMATION
This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or electric hotplate
and can be used either in the extraction mode (ducted to the outside) or in the recirculation mode
(internal recycling).
Before commencing the installation, consideration should be given to the difficulties to be
found during installation and to the bulky weight of the hood. The installation work must be
undertaken by a qualified and competent person in conformity to the rules concerning the
evacuation of contaminated air. The manufacturer disclaims all liability for any damage or
injury caused as a result of not following the instructions for installation contained in the
following text.
2 - COMPONENTS
The cooker hood is made up of the following components (Fig. 1):
2.1 - No. 1 hood canopy C complete with controls, lighting and fan motor
2.2 - No. 1 telescopic chimney stack formed by:
No. 1 U-shaped upper section S
No. 1 U-shaped lower section I
2.3 - No. 1 metal plug T
2.4 - No. 1 plastic bag containing:
No. 1 wall bracket 1 to fix the canopy hood
No. 2 wall brackets 2 to fix the chimney, rawl plugs, screws, and documentation
2.5 - No. 1 splashback B (optional)
3 - SAFETY WARNINGS
3.1 - When used in the extraction mode the cooker hood ducting must not be connected to a flue
which is used for exhausting fumes from appliances supplied with energy other than electric
such as a central heating flue or water heating flue.
3.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with the
voltage on the rating plate inside the hood.
3.3 - Connect the cooker hood to the mains via a double pole switch which has 3 mm clearance
between the contacts.
3.4 - The appliance must be earthed.
3.5 - When istalled, the hood must be positioned at least 65 cm above a cooking appliance.
3.6 - Never do flambé cooking under this cooker hood.
3.7 - Never leave frying pans unattended during use as overheated fats and oils may catch fire.
3.8 - Before carring out any kind of maintenance or cleaning, disconnect the hood from the mains
supply.
3.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such as a
central heating boiler then this must be of the room sealed or balanced flue type. If other types
of flue or appliance are fitted ensure that there is an adequate supply of air into the room.
When the cooker hood is used in conjunction with other appliances supplied with energy other
than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes
being drawn back into the room by the cooker hood.
4 - INSTALLATION
For easy installation proceed as follows:
4.1 - Fix the wall brackets
4.2 - Fix the canopy