NOTE:
If your laptop or PC does not have a DB-9 male connector pin and you
want to connect your laptop or PC directly to the TCX1000-RDM20, use a
combination of the RJ-45 cable and RJ-45 to DB-9 adapter and a USB to
DB-9 male adapter.
To connect the TCX1000-RDM20 to a management console:
1.
Connect one end of the RJ-45 to DB-9 rollover cable to the console port (labeled
SERIAL
). See
and
2.
Connect the other end of the cable directly to a management console or console
server.
Figure 4: Connecting the TCX1000-RDM20 Directly to a Management Console
Figure 5: Connecting the TCX1000-RDM20 to a Management Console Through a Console
Server
Step 6: Power On the TCX1000-RDM20
NOTE:
The TCX1000-RDM20 is supplied with two factory-installed power
supplies, either AC or DC.
NOTE:
We recommend the fuse or circuit protector value rated at 10 A for
both the TCX1000-RDM20-AC and the TCX1000-RDM20-DC.
•
Connecting AC Power to the TCX1000-RDM20 on page 8
•
Connecting DC Power to the TCX1000-RDM20 on page 9
7
Copyright © 2018, Juniper Networks, Inc.
Step 6: Power On the TCX1000-RDM20