CHAPTER 19
Maintaining Cooling System Components
•
Removing a Fan Module from a TCX1000-RDM20 on page 117
•
Installing a Fan Module in a TCX1000-RDM20 on page 118
Removing a Fan Module from a TCX1000-RDM20
The fan modules in a TCX1000-RDM20 are hot-removable and hot-insertable
field-replaceable units (FRUs)—you can remove and replace them without powering off
the TCX1000-RDM20 or disrupting TCX1000-RDM20 functions.
NOTE:
The fan module must be replaced within 96 hours of fan failure.
CAUTION:
Replace the fan module within two minutes of removal to prevent
chassis overheating. Before removing the fan module, ensure that you have
a replacement fan module available.
Before you remove a fan module from a TCX1000-RDM20, ensure that you have taken
the necessary precautions to prevent electrostatic discharge (ESD) damage (see
“Prevention of Electrostatic Discharge Damage” on page 178
).
Ensure that you have the following parts and tools available:
•
ESD grounding strap
•
Antistatic bag or an antistatic mat
To remove a fan module from a TCX1000-RDM20 (see
):
1.
Place the antistatic bag or the antistatic mat on a flat, stable surface.
2.
Attach an ESD grounding strap to your bare wrist to prevent damage to the equipment
caused by static discharge. Connect the strap to one of the ESD points on the chassis.
3.
Begin by loosening the captive thumb screws on the installed fan unit.
117
Copyright © 2019, Juniper Networks, Inc.
Summary of Contents for TCX1000-RDM20
Page 8: ...Copyright 2019 Juniper Networks Inc viii TCX1000 Programmable ROADM Hardware Guide...
Page 14: ...Copyright 2019 Juniper Networks Inc xiv TCX1000 Programmable ROADM Hardware Guide...
Page 16: ...Copyright 2019 Juniper Networks Inc 2 TCX1000 Programmable ROADM Hardware Guide...
Page 22: ...Copyright 2019 Juniper Networks Inc 8 TCX1000 Programmable ROADM Hardware Guide...
Page 30: ...Copyright 2019 Juniper Networks Inc 16 TCX1000 Programmable ROADM Hardware Guide...
Page 34: ...Copyright 2019 Juniper Networks Inc 20 TCX1000 Programmable ROADM Hardware Guide...
Page 40: ...Copyright 2019 Juniper Networks Inc 26 TCX1000 Programmable ROADM Hardware Guide...
Page 42: ...Copyright 2019 Juniper Networks Inc 28 TCX1000 Programmable ROADM Hardware Guide...
Page 62: ...Copyright 2019 Juniper Networks Inc 48 TCX1000 Programmable ROADM Hardware Guide...
Page 64: ...Copyright 2019 Juniper Networks Inc 50 TCX1000 Programmable ROADM Hardware Guide...
Page 72: ...Copyright 2019 Juniper Networks Inc 58 TCX1000 Programmable ROADM Hardware Guide...
Page 74: ...Copyright 2019 Juniper Networks Inc 60 TCX1000 Programmable ROADM Hardware Guide...
Page 86: ...Copyright 2019 Juniper Networks Inc 72 TCX1000 Programmable ROADM Hardware Guide...
Page 98: ...Copyright 2019 Juniper Networks Inc 84 TCX1000 Programmable ROADM Hardware Guide...
Page 106: ...Copyright 2019 Juniper Networks Inc 92 TCX1000 Programmable ROADM Hardware Guide...
Page 128: ...Copyright 2019 Juniper Networks Inc 114 TCX1000 Programmable ROADM Hardware Guide...
Page 134: ...Copyright 2019 Juniper Networks Inc 120 TCX1000 Programmable ROADM Hardware Guide...
Page 148: ...Copyright 2019 Juniper Networks Inc 134 TCX1000 Programmable ROADM Hardware Guide...
Page 150: ...Copyright 2019 Juniper Networks Inc 136 TCX1000 Programmable ROADM Hardware Guide...
Page 152: ...Copyright 2019 Juniper Networks Inc 138 TCX1000 Programmable ROADM Hardware Guide...
Page 154: ...Copyright 2019 Juniper Networks Inc 140 TCX1000 Programmable ROADM Hardware Guide...
Page 164: ...Copyright 2019 Juniper Networks Inc 150 TCX1000 Programmable ROADM Hardware Guide...
Page 166: ...Copyright 2019 Juniper Networks Inc 152 TCX1000 Programmable ROADM Hardware Guide...
Page 180: ...Copyright 2019 Juniper Networks Inc 166 TCX1000 Programmable ROADM Hardware Guide...
Page 184: ...Copyright 2019 Juniper Networks Inc 170 TCX1000 Programmable ROADM Hardware Guide...