Troubleshooting with Chassis and Interface Alarm Messages on the SRX550
Services Gateway
When the services gateway detects an alarm condition, it lights the red or yellow alarm LED on the front
panel as appropriate. For a detailed description of the alarm condition, issue the show chassis alarms CLI
command.
There are two classes of alarm messages:
•
Chassis alarms—Indicate a problem with a chassis component such as the cooling system or power
supply.
•
Interface alarms—Indicate a problem with a specific network interface.
Examples:
user@host# run show chassis alarms
4 alarms currently active
Alarm time Class Description
2009-02-05 09:27:11 PDT Major ge-0/0/5: Link down
2009-02-05 09:27:11 PDT Major ge-0/0/6: Link down
user@host> show chassis fpc pic-status
Slot 0 Online FPC
PIC 0 Online 6x GE, 4x GE SFP Base PIC