Installing an AC Power Supply in an SRX4200 Services Gateway
CAUTION:
Do not mix AC and DC power supplies in the same chassis.
To install an AC power supply (see
1.
Attach the ESD grounding strap to your bare wrist, and connect the strap to the ESD
point on the chassis.
2.
If the power supply slot has a cover panel on it, with one hand slide the ejector lever
toward the left until it stops and using the other hand pull the handle of the cover
panel outward to remove it. Save the cover panel for later use.
3.
Taking care not to touch power supply pins, leads, or solder connections, remove the
power supply from the bag.
4.
Using both hands, place the power supply in the power supply slot on the rear panel
of the services gateway and slide it in until it is fully seated and the ejector lever fits
into place. You will hear a distinct click when the power supply is fully seated in the
chassis.
Figure 21: Installing an AC Power Supply
See Also
Connecting AC Power to an SRX4200 Services Gateway on page 47
•
Replacing a DC Power Supply on the SRX4200
The power supplies are hot-removable and hot-insertable field-replaceable units (FRUs)
installed in the rear panel of the services gateway. You can remove and replace them
without powering off the services gateway or disrupting services gateway functions.
Ensure that you have the following parts and tools available:
•
ESD grounding strap
•
Phillips (+) screwdriver, number 2
57
Copyright © 2019, Juniper Networks, Inc.
Chapter 4: Maintaining Components
Summary of Contents for SRX4200
Page 8: ...Copyright 2019 Juniper Networks Inc viii SRX4200 Services Gateway Hardware Guide...
Page 10: ...Copyright 2019 Juniper Networks Inc x SRX4200 Services Gateway Hardware Guide...
Page 30: ...Copyright 2019 Juniper Networks Inc 30 SRX4200 Services Gateway Hardware Guide...
Page 64: ...Copyright 2019 Juniper Networks Inc 64 SRX4200 Services Gateway Hardware Guide...
Page 70: ...Copyright 2019 Juniper Networks Inc 70 SRX4200 Services Gateway Hardware Guide...