Removing a DC Power Supply Cable from the SRX1500 Services Gateway
To remove a power supply cable connected to a DC power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect
the strap to an approved site ESD grounding point. For more information about ESD,
see
“Preventing Electrostatic Discharge Damage to the SRX1500 Services Gateway”
.
2.
Switch off the external circuit breakers for all the cables attached to the power supply.
Make sure that the voltage across the DC power source cable leads is 0 V and that
there is no chance that the cables might become active during the removal process.
3.
Remove the power cable from the DC power source.
4.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis. For more information about ESD, see
Electrostatic Discharge Damage to the SRX1500 Services Gateway” on page 118
.
5.
Make sure the cable is not touching or in the way of any services gateway components
and that it does not drape where people could trip on it.
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
7.
Attach the power cable to the DC power source.
8.
Verify that the DC source power cabling is correct. If the power cable is correctly
installed and the power supply is functioning normally, the POWER LED on the front
panel glows solid green.
Removing a DC Power Supply on the SRX1500 Services Gateway
Up to two power supplies can be located at the rear of the chassis on the right side. Each
DC power supply weighs approximately 2.20 lbs (1 kg).
CAUTION:
Do not leave a power supply slot empty for more than 30 minutes
while the services gateway is operational. For proper airflow, the power supply
must remain in the chassis, or a blank panel must be used in the empty slot.
NOTE:
After powering off a power supply, wait at least 60 seconds before
turning it back on.
103
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Replacing Power Supply Components
Summary of Contents for SRX1500
Page 8: ...Copyright 2017 Juniper Networks Inc viii SRX1500 Services Gateway Hardware Guide ...
Page 18: ...Copyright 2017 Juniper Networks Inc xviii SRX1500 Services Gateway Hardware Guide ...
Page 20: ...Copyright 2017 Juniper Networks Inc 2 SRX1500 Services Gateway Hardware Guide ...
Page 28: ...Copyright 2017 Juniper Networks Inc 10 SRX1500 Services Gateway Hardware Guide ...
Page 30: ...Copyright 2017 Juniper Networks Inc 12 SRX1500 Services Gateway Hardware Guide ...
Page 34: ...Copyright 2017 Juniper Networks Inc 16 SRX1500 Services Gateway Hardware Guide ...
Page 46: ...Copyright 2017 Juniper Networks Inc 28 SRX1500 Services Gateway Hardware Guide ...
Page 54: ...Copyright 2017 Juniper Networks Inc 36 SRX1500 Services Gateway Hardware Guide ...
Page 58: ...Copyright 2017 Juniper Networks Inc 40 SRX1500 Services Gateway Hardware Guide ...
Page 60: ...Copyright 2017 Juniper Networks Inc 42 SRX1500 Services Gateway Hardware Guide ...
Page 66: ...Copyright 2017 Juniper Networks Inc 48 SRX1500 Services Gateway Hardware Guide ...
Page 78: ...Copyright 2017 Juniper Networks Inc 60 SRX1500 Services Gateway Hardware Guide ...
Page 82: ...Copyright 2017 Juniper Networks Inc 64 SRX1500 Services Gateway Hardware Guide ...
Page 102: ...Copyright 2017 Juniper Networks Inc 84 SRX1500 Services Gateway Hardware Guide ...
Page 104: ...Copyright 2017 Juniper Networks Inc 86 SRX1500 Services Gateway Hardware Guide ...
Page 114: ...Copyright 2017 Juniper Networks Inc 96 SRX1500 Services Gateway Hardware Guide ...
Page 116: ...Copyright 2017 Juniper Networks Inc 98 SRX1500 Services Gateway Hardware Guide ...
Page 130: ...Copyright 2017 Juniper Networks Inc 112 SRX1500 Services Gateway Hardware Guide ...
Page 138: ...Copyright 2017 Juniper Networks Inc 120 SRX1500 Services Gateway Hardware Guide ...
Page 152: ...Copyright 2017 Juniper Networks Inc 134 SRX1500 Services Gateway Hardware Guide ...
Page 168: ...Copyright 2017 Juniper Networks Inc 150 SRX1500 Services Gateway Hardware Guide ...