![Juniper SRX-4600 Hardware Manual Download Page 88](http://html1.mh-extra.com/html/juniper/srx-4600/srx-4600_hardware-manual_2032311088.webp)
Maintaining the SRX4600 Power System
IN THIS SECTION
Maintaining SRX4600 Services Gateway Power Supplies | 90
Replacing an SRX4600 Services Gateway AC Power Supply | 91
Replacing an SRX4600 Services Gateway DC Power Supply | 95
Maintaining SRX4600 Services Gateway Power Supplies
Purpose
For optimum services gateway performance, verify the condition of the power supplies.
Action
On a regular basis:
•
To check the status of the power supplies, issue the show chassis environment pem command. The
output shown below is an example.
user@host>
show chassis environment pem
PEM 0 status:
State Online
Airflow Front to Back
Temperature OK 45 degrees C / 113 degrees F
Temperature OK 39 degrees C / 102 degrees F
Temperature OK 28 degrees C / 82 degrees F
Firmware version 04.10
Fan 0 9232 RPM
DC Output Voltage(V) Current(A) Power(W) Load(%)
12.00 16 192 6
PEM 1 status:
State Online
Airflow Front to Back
Temperature OK 42 degrees C / 107 degrees F
Temperature OK 35 degrees C / 95 degrees F
Temperature OK 26 degrees C / 78 degrees F
Firmware version 04.10
90
Summary of Contents for SRX-4600
Page 1: ...SRX4600 Services Gateway Hardware Guide Published 2020 02 28 ...
Page 18: ......
Page 42: ......
Page 62: ......
Page 82: ......
Page 122: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX4600 127 ...
Page 123: ......
Page 134: ......
Page 147: ...151 ...
Page 150: ...Restricted Access Area Warning 154 ...
Page 157: ...161 ...
Page 170: ...Jewelry Removal Warning 174 ...
Page 173: ...Operating Temperature Warning 177 ...
Page 183: ...DC Power Disconnection Warning 187 ...
Page 187: ...DC Power Wiring Sequence Warning 191 ...
Page 190: ...DC Power Wiring Terminations Warning 194 ...
Page 193: ...DC Power Disconnection Warning 197 ...
Page 197: ...DC Power Wiring Sequence Warning 201 ...