![Juniper SRX-4600 Hardware Manual Download Page 73](http://html1.mh-extra.com/html/juniper/srx-4600/srx-4600_hardware-manual_2032311073.webp)
2. Position the grounding lug over the protective earthing terminal on the side of the chassis, which is
visible through the mounting bracket.
3. Secure the grounding lug to the protective earthing terminal with the two washers and screws. See
.
Figure 30: Connecting a Grounding Cable to an SRX4600 Services Gateway
g009510
4. Dress the grounding cable and ensure that it does not touch or block access to other device components
and that it does not drape where people could trip over it.
Connecting AC Power to an SRX4600 Services Gateway
The SRX4600 Services Gateway is shipped from the factory with two power supplies. Each power supply
is a field-replaceable unit (FRU). You can install replacement power supplies without powering off the
services gateway or disrupting the services gateway function.
Ensure that you have a power cord appropriate for your geographical location available to connect AC
power to the services gateway.
Before you begin connecting AC power to the services gateway:
•
Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage
(see
“Prevention of Electrostatic Discharge Damage” on page 181
•
Ensure that you have connected the services gateway chassis to earth ground.
75
Summary of Contents for SRX-4600
Page 1: ...SRX4600 Services Gateway Hardware Guide Published 2020 02 28 ...
Page 18: ......
Page 42: ......
Page 62: ......
Page 82: ......
Page 122: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX4600 127 ...
Page 123: ......
Page 134: ......
Page 147: ...151 ...
Page 150: ...Restricted Access Area Warning 154 ...
Page 157: ...161 ...
Page 170: ...Jewelry Removal Warning 174 ...
Page 173: ...Operating Temperature Warning 177 ...
Page 183: ...DC Power Disconnection Warning 187 ...
Page 187: ...DC Power Wiring Sequence Warning 191 ...
Page 190: ...DC Power Wiring Terminations Warning 194 ...
Page 193: ...DC Power Disconnection Warning 197 ...
Page 197: ...DC Power Wiring Sequence Warning 201 ...