QFX5220 Clearance Requirements for Airflow and Hardware Maintenance
When planning the site for installing a QFX5220, you must allow sufficient clearance around the installed
chassis (see
and
Figure 29: Clearance Requirements for Airflow and Hardware Maintenance for a QFX5220-32CD
g051087
18.99 in.
(48.23 cm)
Clearance required
for maintenance
22.79 in. (57.88 cm)
FRUs
Ports
17.26 in.
(43.84 cm)
Clearance required
for maintenance
21.1 in. (53.59 cm)
30 in. (76.2 cm)
24 in. (61.0 cm)
Figure 30: Clearance Requirements for Airflow and Hardware Maintenance for a QFX5220-128C
g051193
FRUs
19.0 in.
(48.23 cm)
Ports
17.32 in.
(44.00 cm)
29.00 in. (73.66 cm)
Clearance required
for maintenance
29.25 in. (74.30 cm)
Clearance required
for maintenance
30 in. (76.2 cm)
24 in. (61.0 cm)
•
For the cooling system to function properly, the airflow around the chassis must be unrestricted. See
“QFX5220 Cooling System” on page 52
for more information about the airflow through the chassis.
86