Table 131: Alarm Terms and Definitions (continued)
Definition
Term
Seriousness of the alarm. The level of severity can be either major (red) or minor (yellow).
•
Major (red)—Indicates a critical situation on the device that has resulted from one of the following
conditions. A red alarm condition requires immediate action.
•
One or more hardware components have failed.
•
One or more hardware components have exceeded temperature thresholds.
•
An alarm condition configured on an interface has triggered a critical warning.
•
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked,
might cause an interruption in service or degradation in performance. A yellow alarm condition
requires monitoring or maintenance. For example, a missing rescue configuration generates a
yellow system alarm.
Alarm severity
levels
Alarms include the following types:
•
Chassis alarm—Predefined alarm triggered by a physical condition on the device such as a power
supply failure or excessive component temperature.
•
Interface alarm—Alarm you configure to alert you when an interface link is down. Applies to
ethernet, fibre-channel, and management-ethernet interfaces. You can configure a red (major)
or yellow (minor) alarm for the link-down condition, or have the condition ignored.
•
System alarm—Predefined alarm that might be triggered by a missing rescue configuration, failure
to install a license for a licensed software feature, or high disk usage.
Alarm types
Chassis Alarm Messages
Chassis alarms indicate a failure on the device or one of its components. Chassis alarms are preset and
cannot be modified.
Chassis alarms on QFX5100, QFX5110, QFX5210, and QFX5120 devices have two severity levels:
•
Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions
described in
. A red alarm condition requires immediate action.
•
Minor (yellow)—Indicates a noncritical condition on the device that, if left unchecked, might cause an
interruption in service or degradation in performance. A yellow alarm condition requires monitoring or
maintenance.
describes the chassis alarm messages on QFX5100, QFX5110, QFX5200, QFX5210,
and QFX5120 devices.
624
Summary of Contents for QFX3500
Page 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Page 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Page 229: ...205...
Page 238: ...Unterminated Fiber Optic Cable Warning 214...
Page 246: ...Restricted Access Warning 222...
Page 249: ...225...
Page 257: ...Jewelry Removal Warning 233...
Page 260: ...Operating Temperature Warning 236...
Page 271: ...DC Power Disconnection Warning 247...
Page 275: ...DC Power Wiring Sequence Warning 251...
Page 278: ...DC Power Wiring Terminations Warning 254...
Page 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Page 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Page 565: ...Table 105 System Information continued Description Field Inventory details 541...