of the light signal during transmission. Passive media components such as cables, cable
splices, and connectors cause attenuation. Although attenuation is significantly lower
for optical fiber than for other media, it still occurs in both multimode and single-mode
transmission. An efficient optical data link must transmit enough light to overcome
attenuation.
Dispersion
is the spreading of the signal over time. The following two types of dispersion
can affect signal transmission through an optical data link:
•
Chromatic dispersion, which is the spreading of the signal over time caused by the
different speeds of light rays.
•
Modal dispersion, which is the spreading of the signal over time caused by the different
propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or
attenuation, usually limits the maximum bit rate and link length. For single-mode
transmission, modal dispersion is not a factor. However, at higher bit rates and over longer
distances, chromatic dispersion limits the maximum link length.
An efficient optical data link must have enough light to exceed the minimum power that
the receiver requires to operate within its specifications. In addition, the total dispersion
must be within the limits specified for the type of link in Telcordia Technologies document
GR-253-CORE (Section 4.3) and International Telecommunications Union (ITU)
document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as
a power penalty in the power budget. The optical power budget must allow for the sum
of component attenuation, power penalties (including those from dispersion), and a
safety margin for unexpected losses.
See Also
Calculating the Fiber-Optic Cable Power Budget for an NFX150 Device on page 51
•
•
Calculating the Fiber-Optic Cable Power Margin for an NFX150 Device on page 52
Calculating the Fiber-Optic Cable Power Budget for an NFX150 Device
Calculate the link's power budget when planning fiber-optic cable layout and distances
to ensure that fiber-optic connections have sufficient power for correct operation. The
power budget is the maximum amount of power the link can transmit. When you calculate
the power budget, you use a worst-case analysis to provide a margin of error, even though
all the parts of an actual system do not operate at the worst-case levels.
To calculate the worst-case estimate for fiber-optic cable power budget (P
B
) for the
link:
1.
Determine values for the link's minimum transmitter power (P
T
) and minimum receiver
sensitivity (P
R
). For example, here, (P
T
) and (P
R
) are measured in decibels, and decibels
are referenced to 1 milliwatt (dBm).
P
T
= –15 dBm
51
Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Site Planning, Preparation, and Specifications
Summary of Contents for NFX150
Page 8: ...Copyright 2018 Juniper Networks Inc viii NFX150 Network Services Platform Hardware Guide...
Page 18: ...Copyright 2018 Juniper Networks Inc xviii NFX150 Network Services Platform Hardware Guide...
Page 40: ...Copyright 2018 Juniper Networks Inc 40 NFX150 Network Services Platform Hardware Guide...
Page 108: ...Copyright 2018 Juniper Networks Inc 108 NFX150 Network Services Platform Hardware Guide...
Page 116: ...Copyright 2018 Juniper Networks Inc 116 NFX150 Network Services Platform Hardware Guide...
Page 152: ...Copyright 2018 Juniper Networks Inc 152 NFX150 Network Services Platform Hardware Guide...