Press the online/offline button on the MIC. Use a narrow-ended tool that fits inside the opening
that leads to the button. Press and hold the button until the MIC LED goes off (about 5 seconds).
•
Issue the following CLI command:
user@host>
request chassis mic fpc-slot
fpc-slot
mic-slot
mic-slot
offline
For more information about the command, see the
Junos OS System Basics and Services Command
.
3. Unplug the cable from the cable connector port. If the MIC uses fiber-optic cable, immediately cover
each transceiver and the end of each cable with a rubber safety cap.
WARNING:
Do not look directly into a fiber-optic transceiver or into the ends
of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected
to a transceiver emit laser light that can damage your eyes.
CAUTION:
Do not leave a fiber-optic transceiver uncovered except when
inserting or removing cable. The safety cap keeps the port clean and prevents
accidental exposure to laser light.
4. Remove the cable from the cable manager, and detach it from the destination port.
SEE ALSO
Installing a Cable on an MX2010 MPC or MIC | 445
Preventing Electrostatic Discharge Damage to an MX Series Router
Installing a Cable on an MX2010 MPC or MIC
To install a MIC cable or an MPC cable (see
and
):
1. Have ready a length of the type of cable used by the component. For cable specifications, see the
Series Interface Module Reference
.
2. If the cable connector port is covered by a rubber safety cap, remove the cap.
445
Summary of Contents for MX2010
Page 1: ...MX2010 Universal Routing Platform Hardware Guide Published 2019 12 03...
Page 28: ......
Page 30: ...MX2010 Power System Description 95 MX2010 Cooling System Description 45 4...
Page 144: ...MX2010 DC Power 48 V System Electrical Specifications 201 122...
Page 146: ......
Page 233: ......
Page 273: ...Figure 98 Loading the MX2010 Router into the Rack g007436 256...
Page 294: ...Figure 113 Reinstalling an AC Power Distribution Module g007440 D 277...
Page 295: ...Figure 114 Reinstalling a DC Power Distribution Module 48 V D g007432 278...
Page 373: ...4 PART Installing and Replacing Components Installing Components 359 Replacing Components 429...
Page 374: ......
Page 620: ......
Page 715: ...6 PART Troubleshooting Hardware Troubleshooting Components 703...
Page 716: ......
Page 744: ......
Page 772: ......
Page 775: ...763...
Page 783: ...772...
Page 796: ...Jewelry Removal Warning 787...
Page 799: ...Operating Temperature Warning 790...
Page 808: ...DC Power Disconnection Warning 799...
Page 812: ...DC Power Wiring Sequence Warning 803...