CHAPTER 1
MX2010 Router Overview
IN THIS CHAPTER
MX2010 Router Overview
The MX2010 Universal Routing Platform is an Ethernet-optimized router that provides both switching
and carrier-class Ethernet routing. The MX2010 router supports service provider core, converged core
and edge, and edge applications, and enables a wide range of business and residential and services, including
high-speed transport and VPN services, next-generation broadband multiplay services, and high-volume
Internet data center internetworking.
The MX2010 chassis provides redundancy and resiliency. All major hardware components including the
power system, the cooling system, the Control Board and the switch fabrics are fully redundant.
The MX2010 router is 34 rack units (U) tall. One router can be installed in an open-frame rack, four-post
rack, or cabinet. The MX2010 router has 10 dedicated line-card slots which means a maximum of 10
Modular Port Concentrators (MPCs) including adapter cards (ADCs), and Modular Interface Cards (MICs),
a host subsystem consisting of 2 Control Board with Routing Engines (CB-REs), and 8 Switch Fabric Boards
(SFBs).
Up to 2 MICs can be installed in each MPC. Fully populated, the MX2010 router supports up to 20 MICs.
For a list of the supported MPCs, and MICs, see the
MX Series Interface Module Reference
.
RELATED DOCUMENTATION
MX2010 Component Redundancy | 14
MX2010 Physical Specifications | 130
MX2010 Chassis Description | 7
MX2000 Host Subsystem CB-RE Description | 51
MX2010 Craft Interface Description | 29
3
Summary of Contents for MX2010
Page 1: ...MX2010 Universal Routing Platform Hardware Guide Published 2019 12 03...
Page 28: ......
Page 30: ...MX2010 Power System Description 95 MX2010 Cooling System Description 45 4...
Page 144: ...MX2010 DC Power 48 V System Electrical Specifications 201 122...
Page 146: ......
Page 233: ......
Page 273: ...Figure 98 Loading the MX2010 Router into the Rack g007436 256...
Page 294: ...Figure 113 Reinstalling an AC Power Distribution Module g007440 D 277...
Page 295: ...Figure 114 Reinstalling a DC Power Distribution Module 48 V D g007432 278...
Page 373: ...4 PART Installing and Replacing Components Installing Components 359 Replacing Components 429...
Page 374: ......
Page 620: ......
Page 715: ...6 PART Troubleshooting Hardware Troubleshooting Components 703...
Page 716: ......
Page 744: ......
Page 772: ......
Page 775: ...763...
Page 783: ...772...
Page 796: ...Jewelry Removal Warning 787...
Page 799: ...Operating Temperature Warning 790...
Page 808: ...DC Power Disconnection Warning 799...
Page 812: ...DC Power Wiring Sequence Warning 803...