Table 57: Setting the JNP10K-PWR-AC2 Dip Switches
Field
State
Switch
IP0 is present
On
1
IP0 is not present
Off
IP1 is present
On
2
IP1 is not present
Off
Enabled for 30 A feed; 5500-W for a single feed, 5000-W for dual feeds
On
3
Enabled for 20 A feed; power supply capacity is 3000-W
Off
15. Verify that the INP1 and INP2 LEDs on the power supply faceplate are lit and are on steadily.
16. Press the power switch to the on (|) position.
How to Remove a JNP10K-PWR-DC Power Supply
The JNP10K-PWR-DC power supply in an MX10016 chassis is a hot-removable and hot-insertable
field-replaceable unit (FRU). You remove DC power supplies from the rear of the chassis.
CAUTION:
Before you remove a power supply, ensure that sufficient power supplies
are left in the chassis to power the router (see
“Power Requirements for MX10016
).
WARNING:
Before performing DC power procedures, ensure that power is removed
from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel
board that services the DC circuit, router the circuit breaker to the OFF position, and
tape the router handle of the circuit breaker in the OFF position.
Before you remove a DC power supply from the router:
187
Summary of Contents for MX10016
Page 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Page 19: ......
Page 86: ......
Page 123: ......
Page 153: ......
Page 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Page 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Page 241: ......
Page 249: ......
Page 277: ...Restricted Access Warning 281 ...
Page 292: ...Jewelry Removal Warning 296 ...
Page 295: ...Operating Temperature Warning 299 ...
Page 304: ...DC Power Disconnection Warning 308 ...
Page 308: ...DC Power Wiring Sequence Warning 312 ...
Page 311: ...DC Power Wiring Terminations Warning 315 ...
Page 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...