SEE ALSO
General Safety Guidelines and Warnings | 313
Grounded Equipment Warning | 328
Removing and Installing MX10000 Power System Components | 191
Connecting AC Power to an MX10000
After you ground the chassis, connect the power supplies, and supply power to the chassis, the system
initiates the power-on sequence. This sequence can start incrementally with a single power supply, but it
is not recommended that you bring up an MX10000 system with at less than three power supplies.
Before you begin to connect power to the router, be sure you understand how to prevent ESD damage.
See
“Prevention of Electrostatic Discharge Damage” on page 343
To connect AC power to an MX10000 chassis:
1. Connect the chassis to earth ground (see
“Connecting an MX10000 to Earth Ground” on page 160
).
CAUTION:
To meet safety and electromagnetic interference (EMI) requirements and
to ensure proper operation, an MX10000 must be adequately grounded before it is
connected to power.
For installations that require a separate grounding conductor to the chassis, use the
protective earthing terminal on the rear panel of the MX10000 to connect to the
earth ground.
An MX10000 gets additional grounding when you plug the power supply in the router
into a grounded AC power outlet by using the AC power cord appropriate for your
geographical location. See
“MX10000 Power Cables Specifications” on page 107
.
2. Install power supplies in the router and apply power. See
“How to Install a JNP10K-PWR-AC Power
or
“How to Install a JNP10K-PWR-AC2 Power Supply” on page 208
.
SEE ALSO
JNP10K-PWR-AC Power Supply | 61
How to Install a JNP10K-PWR-AC Power Supply | 196
Connecting an MX10000 to Earth Ground | 160
163
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...