Intrusion Detection and Prevention (IDP) 4.2
2
Steps to Deploy a New IDP 8200 with New I/O Modules
Figure 2: Replacing the Blank Tray with the I/O Module Tray
5.
Tighten the screws on each side of the faceplate.
6.
Power on the device. Verify that the green POWER LED lights steadily.
7.
Complete the initial appliance configuration and “Advanced ACM
Configuration” workflow, as described in Chapter 5 of the
Juniper Networks
Intrusion Detection and Prevention Installation Guide.
8.
For IDP 8200 appliances running software version 4.2r1, you must download
and install an updated network driver patch to support the following I/O
modules.
I/O modules not listed do not require the updated network driver patch.
For detailed procedures, see “Downloading and Installing the Updated Network
Driver Patch IDP 8200” on page 4.
9.
Connect the forwarding interfaces to your network, as described in Chapter 5 of
the
Juniper Networks Intrusion Detection and Prevention Installation Guide.
10. Verify traffic flow, as described in Chapter 5 of the
Juniper Networks Intrusion
Detection and Prevention Installation Guide.
11. Add the sensor to NSM, as described in Chapter 6 of the
Juniper Networks
Intrusion Detection and Prevention Installation Guide
.
IDP-1GE-4SX-BYP
4-port 1 GigE SX fiber interface card with bypass
IDP-10GE-2SR-BYP
2-port 10 GigE SR interface card with bypass
IDP-10GE-2XFP
2-port 10 GigE XFP interface card (non-bypass)