Routine Maintenance Procedures for EX9251
Switches
IN THIS SECTION
Routine Maintenance Procedures for EX9251 Switches | 116
Maintaining the Routing Engine in EX9251 Switches | 117
Routine Maintenance Procedures for EX9251 Switches
IN THIS SECTION
Purpose
For optimum performance of an EX9251 switch, perform preventive maintenance procedures.
Action
• Inspect the installation site for moisture, loose wires or cables, and excessive dust. Make sure that
airflow is unobstructed around the switch and into the air intake vents.
• Check the status-reporting devices on the front panel in EX9251 switches—alarms and LEDs.
• Inspect the air filter or fan tray at the rear of the switch, replacing it every 6 months for optimum
cooling system performance. Do not run the switch for more than a few minutes without the air filter
or fan tray in place.