Table 1: Events Detected by AI-Scripts (continued)
EVENT ID
DESCRIPTION
CHASSISD_RE_OVER_TEMP_SHUTDOWN The chassis process (chassisd) performed the indicated action because
the temperature of the indicated Routing Engine exceeded the maximum
threshold for more than four minutes. Continued operation at the excessive
temperature could damage device components.
CHASSISD_RE_OVER_TEMP_WARNING The
temperature of the indicated Routing Engine exceeded the indicated
temperature, which is the upper of two thresholds. If the temperature does
not go below the threshold within four minutes after the chassis process
(chassisd) detects this condition, chassisd shuts down the indicated
component. When this message was logged, the indicated number of
seconds remained before shutdown.
CHASSISD_SBE_DETECTED Too
many
single-bit correctable ECC parity errors were detected in
Routing Engine DRAM.
CHASSISD_SIB_INVALID_SLOT
The chassis process (chassisd) detected the presence of a Switch
Interface Board (SIB) in an invalid slot. The SIB remains offline.
CHASSISD_SMB_INVALID_PS
The chassis process (chassisd) could not set the status (enabled or
disabled) for a power supply because it received the indicated power
supply status code, which is invalid.
CHASSISD_SMB_IOCTL_FAILURE
The indicated ioctl() operation failed at the indicated address on the system
management bus (SMB).
CHASSISD_SMB_READ_FAILURE
A read() operation failed at the indicated address on the system
management bus (SMB).
CHASSISD_TEMP_SENSOR_FAILURE
The temperature sensor for the indicated component (field-replaceable
unit, or FRU) either did not respond to a request from the chassis process
(chassisd) for a temperature reading or sent a value that is outside the
normal operating range.
CHASSISD_TIMER_VAL_ERR
The chassis process (chassisd) started a timer to track the timeout period
for an event. The timer returned a null identifier, so chassisd could not
clear the timer.
CHASSISD_UNEXPECTED_EXIT
The chassis process (chassisd) exited unexpectedly and reported the
indicated error.
CHASSISD_VOLTAGE_READ_FAILED
The chassis process (chassisd) could not read the voltage data from the
indicated component (field-replaceable unit, or FRU).
CHASSISD_VOLTAGE_SENSOR_INIT
The chassis process (chassisd) could not initialize the voltage sensor for
the indicated component (field-replaceable unit, for FRU).
CONNECTION_CHASSISD_FAIL
The alarm process (alarmd) was unable to connect to the chassis process
(chassisd).
CONNECTION_CRAFTD_FAIL
The alarm process (alarmd) was unable to connect to the craft process
(craftd).