Figure 39: Power Cord Retainer Installed on the AC PSM for ACX5448-D or ACX5448-M
g100718
1
2
3
4
5
4
—
1
—
AC power cord retainer installed
Input status LED
5
—
2
—
Ejector lever
Output status LED
3
—
Fault LED
Figure 40: Connect an AC Power Cord to the ACX5448-D or ACX5448-M Router
g100715
5. Power on the power supply at source.
Connect Power to a DC Router
gives the DC power system input voltage for ACX5400 routers.
Table 3: ACX5448, ACX5448-D, and ACX5448-M DC Power System Input Voltage
Specification
Item
Rated operating voltage: –48 VDC to –60 VDC
Operating voltage range: –40.8 VDC through –72 VDC
DC input voltage (ACX5448)
Rated operating voltage: –48 VDC to –60 VDC
Operating voltage range: –43.2 VDC through –72 VDC
DC input voltage (ACX5448-D)
Rated operating voltage: –48 VDC to –60 VDC
Operating voltage range: –43.2 VDC through –72 VDC
DC input voltage (ACX5448-M)
22