Jung Tronic SNT 150 Operating Instructions Manual Download Page 4

 

Light Management 

Tronic Transformers 

 

 
 

Avoid sources of heat (e.g. lamps) in the immediate vicinity of the 
transformer. In critical cases, measure the temperature at the Tc point. 
Recommended cross-section and type of secondary cable, fig (5). 

Secondary cable: see technical data, 

fig. (9). 

Power per line 

Wire cross-
section 

Recommended type of 
secondary wire 

 40 W 

 0,75 mm² 

z.B. H 03 V V-F 2 x 0,75 mm² 

50 W – 105 W 

 1,5 mm² 

z.B. H 05 V V-F 2 x 1,5mm² 

110 W – 150 W 

 2,5 mm² 

z.B. H 05 V V-F 2 x 2,5 mm² 

155 W – 200 W 

distribute power to at least 2 lines (min. 2 x 1,5 
mm²) 

Figure 5 

If several lamp circuits are to be connected to a transformer, it is 
recommended to use a distributor, fig. (6). 

 

Figure 6 

The secondary line must not be connected to the secondary line of other 
TRONIC transformers and not be laid close to the mains supply line, fig. 
(7). 

 

Figure 7 

 