background image

 

Temperature Management 

Room temperature controller 

Ref.-no.: TR..231.., TR..241.., 

TR..236.., TR..246.. 

 

 

Fig. 

c

 

3. Connection 

1.  Carry out the electrical connection according to the respective wiring 
 

diagram (Fig. (2) or Fig. (3). 

Note:

 

Ensure that the neutral conductor N is connected to terminal N. 
Considerable fluctuations in temperature may otherwise occur. Conductor 
cross-section: 1 to 2.5 mm2 solid conductor. 

Symbols used in the wiring diagram: 

L  

= L conductor 

N  

= N- conductor 

 

= Connection for clock signal to reduce temperature 

  

Heating 

 = 

Cooling 

RF  

= Resistor for thermal feedback 

TA  

= Resistor for night reduction of room temperature 

2.  Clip the rocker (

A

 in Fig. 

c

) on the switch in the flush insert. 

3.  Place the center plate together with the frame on the flush insert. The 
 

center plate must snap in place in the top left of the housing base. 

4.  Tighten the screw (

B

). 

5.  Clip on the setting knob (

C

). 

Reviews: