After 4 hours the motion detector switches to automatic mode. 

Operating mode: switch light off for 4 hours 

Press installation button 3 x. 
Light switches off for 4 hours. 
The red LED lights up. 
After 4 hours the motion detector switches to automatic mode. 

Operating mode: switch on test operation 

Press installation button 4 x. 
The red and green LEDs light up. 
The test mode is active. Each time motion is detected, the motion detector switches on for 
approx. 3 seconds independently of the brightness. 
The yellow LED lights up briefly each time a motion is detected. 

Performing a reset 

Press installation button longer than 4 seconds. 
A reset is performed. The motion detector is in automatic mode. 

Configuring the motion detector 

The three adjusters can be used to set the run-on time, the brightness, the sensitivity and a 
short-time operation. 

picture 4 

Set follow-up time 

The light remains switched on for this time after the last movement detection. The run-on time is 
set in a range from approx. 2 seconds to 30 minutes.  

Turn the 

time

 adjuster (7) to the required position (picture 4). 

The motion detector switches off after 90 minutes at the latest even when there is constant 
motion in the detection area. Switch-on only takes place again if the brightness is below the 
preset value and there movement is again detected in the detection area. 

Setting the brightness threshold 

Only when the brightness drops below the threshold will the light be switched on when there is 
motion in the detection area. The brightness threshold is steplessly adjustable in a range from 
approx. 1 to 1000 lux.  

4/15 

32536423 
J:0082536423 

26.07.2010 

Observer 220 

Summary of Contents for Observer 220

Page 1: ...voltage Danger of electric shock Always disconnect before carrying out work on the devise or load At the same time take into account all circuit breakers that supply dangerous voltage to the device or...

Page 2: ...n Protected against spray water Follow up time sensitivity and brightness value settable Test operation for checking the detection area Switch light on or off for 4 hours Short time operation to contr...

Page 3: ...threshold for 2 minutes 4 Operation Notes on setting the operating mode The operating mode can be changed using an installation button NC contact Depending on the desired operating mode the installati...

Page 4: ...tector The three adjusters can be used to set the run on time the brightness the sensitivity and a short time operation picture 4 Set follow up time The light remains switched on for this time after t...

Page 5: ...on In short time operation when motion is detected a pulse of 0 5 seconds is generated that can be used e g to activate a bell This operating mode functions independently of the brightness picture 5 o...

Page 6: ...ns of self adhesive cover plate elements The cover plate elements picture 7 are pre punched for all 5 cover layers and can be trimmed to the desired angle Do not interchange the right side and left si...

Page 7: ...r plate elements to the left side of the sensor window picture 8 i Due to the complex structure of the motion detector sharp delimitation of the hidden area is not possible in all cases Example 2 Hidi...

Page 8: ...al connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cover u...

Page 9: ...nsor head Low temperature difference Installation height less than 2 4 m Effects of weather e g rain or snow The range is increased in the case of The land slopes downwards away from the motion detect...

Page 10: ...out condensation water holes 10 picture 14 Exception installation in dusty rooms The connection box has 6 cable entries 11 that are provided with moulded in rubber sheaths The supply and power cables...

Page 11: ...ter screw holes 12 picture 14 Connecting and installing the motion detector picture 15 Terminals The connecting cables are preassembled with screwless terminals brown BN relay lamp cable black BK L ex...

Page 12: ...g switched on on the power cable and also switch on The motion detector with the longest run on time determines the switch on time i All motion detectors connected in parallel must be operated on the...

Page 13: ...rightness threshold and sensitivity see Operation 6 Appendix 6 1 Technical data Rated voltage AC 230 240 V Power consumption approx 1 1 W Ambient temperature 20 55 C Protection rating IP 55 Circuit br...

Page 14: ...e g ventilation cooling light bulbs trees and bushes Align sensor head stick cover plate elements on sensor window or reduce sensitivity sens Cause 2 Operating mode Light on for 4 hours is switched o...

Page 15: ...GMBH CO KG Volmestra e 1 D 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 1 89 E mail mail info jung de Internet www jung de www jung katalog de 15 15 32536423 J 0082536423 26 07 201...

Reviews: