Emergency system set and emergency system set with UPS
01.10.2020
7 / 11
0024015123
Service unit
Corridor
UPS module
only included in the emergency system set with UPS
Toilet for people
with disabilities
Fig. 11: Installation situation
+24V
M
GND
+24V
M GND
KW
KR
KA
+24VE GNDE
RT BL AT
RL
WC
R
TWC
R
TWC\ +24V
AT AT
\
15
4
8
1
Service unit
Reset button
AT AT
\
further
reset button
Pull cord
push-button
Emergency
signal
RL
WC
R
TWC
R
TWC\ +24V
further
pull cord
push-button
AC 230 V~
+24V
GND
11
Power supply
14
M GND
GND
UPS module
only in
emergency system
set with UPS
+24V IN
+24V OUT
Fig. 12: Wiring pull cord push-button