6. Technical data 

KNX-medium  

TP1 

Start-up mode  

S-Mode 

KNX supply 

KNX 21...32 V DC 

KNX power consumption 

typ. 450 mW 

KNX connection  

KNX Anschlussklemme 

External supply 

Rated voltage  

AC/DC 24 V SELV 

Power consumption  

max. 7,5 W 

Connection Connecting terminal yellow/white 

Ambient conditions 

Ambient temperature 

-20 °C … +55 °C  
(no icing and no soiling) 

Storage temperature 

-40 °C … +70 °C 

Box 

Type of protection 

IP 44 (position of normal use) 

Safety class  

III 

Dimensions (L x W x H) 

approx. 88 x 170 x 204 mm 
(incl. mounting bracket) 

Weight 

ca. 240 g 

Sensor signals 

Temperature 

Measuring range  

approx. -20 ... +55 °C 

Accuracy 

± 1 K (Windgeschw. > 0,5 m/s) 

Wind speed 

Measuring range 

ca. 0 ... 40 m/s 

Accuracy 

± 2 m/s 

Precipitation 

Measuring range 

precipitation yes / no 

Sensitivity fine 

drizzle 

Shut-off delay 

adjustable 

Brightness 

Cardinal points  

Ost, Süd, West 

Measuring range  

ca. 1 ... 110 klx 

Spectral range  

700 ... 1050 nm 

Accuracy 

10 % (upper end of measuring range) 

Twilight 

Cardinal point  

south 

Measuring range 

ca. 0 ... 674 lx 

Spectral range 

700 ... 1050 nm 

Accuracy 

10 % (upper end of measuring range) 

7. Accessories 

Power supply g AC 24 V ~  

WSSV10 

 