Operating manual: FRWM-AR Alarm relay
35
EN
EN
9 Faults/error messages
FRWM-AR not in the default status
If the FRWM-AR is not in the default status,
please follow the instructions under 7 "Restore
default status"on page 33.
Radio group has reached the
available number of participants
Please set up the radio group again.
First set the master, and then connect
the desired number of FRWM smo-
ke alarms one after another. Please note
that the FRWM-AR must be the last par-
ticipant integrated into the radio group.
Possible faults when integrating
into the radio group:
All faults are indicated by the Status-LED flas-
hing red briefly.
Possible fault causes:
Radio range
A possible cause of a fault may be that the
radio range between the radio group parti-
cipants is exceeded or that the radio waves
are too strongly shielded by walls, furniture
or closed doors. To resolve the fault, plea-
se align the radio group participants again
and reduce the distance between them.
Radio group not in learning mode
If the FRWM radio group is not in learning
mode, please follow the instructions under
4.4 "Set the radio group into learning mode"
on page 31.