o
Disconnect all connections or reset repeater to default setting (see Disconnecting
connection to a radio transmitter or actuator or Resetting repeater to default setting).
i
Radio transmitters and actuators can be connected to each other as described in the
instructions of the radio transmitters and actuators.
The repeater only repeats radio telegrams from specific devices
Figure 3: Multistage commissioning
If the repeater does not repeat all radio telegrams of a system, multistage commissioning takes
place.
o
Step
A
Connect repeater to radio transmitter (see Connecting repeater to radio transmitter).
o
Step
B
Connect repeater to actuator (see Connecting repeater to actuator).
o
Step
C
Connect radio transmitters and actuators to each other as described in the instructions of
the radio transmitters and actuators.
Two repeaters, switched in sequence, only repeat radio telegrams from certain devices
i
If two repeaters are switched in sequence, then connect both the transmitter and the
actuator/energy sensor with both repeaters. During the connection operation, the repeater
and transmitter or actuator/energy sensor must be within radio range of one another.
o
Step
A
Connect repeaters 1 and 2 to the radio transmitter (see Connecting repeater to radio
transmitter).
o
Step
B
Connect repeaters 1 and 2 to the actuator (see Connecting repeater to actuator).
o
Step
C
Connect radio transmitters and actuators to each other as described in the instructions of
the radio transmitters and actuators.
Connecting repeater to radio transmitter
o
Press button
Prog
(3) for longer than 4 seconds.
The status LED (2) flashes after 4 seconds. The repeater is in programming mode for
approx. 1 minute.
o
Switch radio transmitter to programming mode (see radio transmitter instructions).
o
Trigger telegram on the radio transmitter.
The status LED (2) lights up for 5 seconds.
3/5
82586533
J0082586533
27.03.2017
eNet radio repeater in SCHUKO housing