background image

eNet radio repeater in SCHUKO housing

eNet radio repeater in SCHUKO housing

Art. No. : FMR100SGWW

Operating instructions

1 Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Adapter plugs may not be connected in series and must be easily accessible.

The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: Repeater

(1) SCHUKO

® 

socket with increased contact protection

(2) Red status LED, covered
(3) Prog button

3 Function

Intended use

-

Receiving and repeating eNet radio telegrams

-

Extending the range of radio transmitters and actuators

-

Indoor mounting in SCHUKO®

 

socket or socket with ground pin

Product characteristics

-

Fully encrypted radio transmission (AES-CCM) from eNet Server software version 2.0

-

Repeating of all received radio telegrams or only of selected radio transmitters and
actuators

-

125 transmitters/actuators can be connected

-

Two repeaters are cascadable

1/5

82586533
J0082586533

27.03.2017

Summary of Contents for FMR100SGWW

Page 1: ...ergency stop and emergency call These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Repeater 1 SCHUKO socket with increased contact protection 2 Red status LED covered 3 Prog button 3 Function Intended use Receiving and repeating eNet radio telegrams Extending the range of radio transmitters and actuators Indoor mounting in SCHU...

Page 2: ...ctrical connection Mounting To ensure good transmission quality keep a sufficient distance from any possible sources of interference e g metallic surfaces microwave ovens hi fi and TV systems ballasts or transformers o Insert device into socket outlet 4 2 Commissioning DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before working on the device cover up live part...

Page 3: ...peat radio telegrams from certain devices i If two repeaters are switched in sequence then connect both the transmitter and the actuator energy sensor with both repeaters During the connection operation the repeater and transmitter or actuator energy sensor must be within radio range of one another o Step A Connect repeaters 1 and 2 to the radio transmitter see Connecting repeater to radio transmi...

Page 4: ... transmitter The repeater and radio transmitter exit the programming mode automatically Disconnecting connection to an actuator or energy sensor i All the connections to an actuator or energy sensor are disconnected o Carry out the same steps as when connecting see Connecting repeater to actuator or energy sensor The status LED 2 of the repeater and the status LED on the actuator or energy sensor ...

Page 5: ...nce The transmitter and actuator energy sensor are not connected to both repeaters Connect both the transmitter and the actuator energy sensor with both repeaters Radio transmitter does not receive any feedback from the actuator Cause Only the radio transmitter is connected to the repeater Connect actuator to repeater 5 3 Conformity Albrecht Jung GmbH Co KG hereby declares that the radio system ty...

Reviews: