Function block 1: Extend minimum runontime
(10 seconds) by the selected value
START
,
STOP
Function block 1: Extend minimum runontime
(10 seconds) individually
Set-up buttons, IR remote control
Button
Function
Ù
Walking test – Check detection field
Ú
Reset sensitivity, brightness threshold and
runontime to presetting. Press for at least 3
seconds
Operation with IR remote control
If enabled, function block 1 can be operated manually by remote control. In manual operation,
brightness and motion detection for function block 1 are switched off until automatic mode is
reset.
o
Switch on, e.g. light: Press
¿
button.
o
Switch off, e.g. light: Press
Á
button.
o
Set automatic mode: Press
À
button.
Manually change settings with IR remote control
If enabled, individual settings for function block 1 can be changed during operation using a
remote control.
Sensitivity:
o
Increase sensitivity: Press
´
button.
o
Decrease sensitivity: Press
²
button.
o
Recall set sensitivity: Press
³
button.
i
The manual adjustment of sensitivity by the adjuster
Sens.
(6) is overwritten by the IR
remote control and vice versa.
Brightness threshold:
o
Change brightness threshold: Depending on requirement, press
Ê
button,
Ë
button,
Ì
button or
Í
button.
o
Set current brightness as brightness threshold: Press
É
button.
Runontime: The preset runontime of 10 seconds can be extended individually.
o
Extend runontime: Depending on requirement, press
10 SEK
button,
30 SEK
button,
2
MIN
button,
5 MIN
button or
30 MIN
button. Other values can be set with the
START
/
STOP
buttons.