1. Safety warnings 

Attention: Electrical equipment must be installed and fitted only by 
qualified electricians. Risk of electric shock! Risk of electric shock 
in the event of malfunction, if the device is fitted in combination with 
230 V socket outlets under one cover. For fastening to the 
supporting ring, use only the plastic screws supplied with the 
device. Failure to observe any of the installation instructions may 
cause damage to the device and result in fire and other hazards. 
Risk of damage to the device due to electrostatic discharge. Use 
only the plastic screws supplied with the device. 

2. Function  

System information  

This device is a product of the KNX system and complies with KNX 
directives. Detailed technical knowledge obtained in KNX training courses 
is a prerequisite to proper understanding. The functionality of this device 
depends on the software. Detailed information on loadable software and 
attainable functionality as well as the software itself can be obtained from 
the manufacturer’s product database. Planning, installation and 
commissioning of the unit is effected by means of KNX-certified software. 
The full functionality with KNX commissioning software from version 
ETS3.0d. onwards. The product database, technical descriptions and 
conversion programs and other utilities are available in the Internet at 
www.jung.de 

Function 

Touch sensor for switching, dimming, shutter operation, value 
transmission, recall and storage of lightscenes. Each key rocker is 
‚divided‘ into an upper and a lower half (FIG. 

A

) and has a function 

assigned to it. Each rocker is equipped with a red status LED. 
The blue operation LED can be used as an orientation light besides 
indicating the programming state of the touch sensor module. 

Stand: Jul-08  3

25 588 03

 

Summary of Contents for 30XX TSM Series

Page 1: ...directives Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding The functionality of this device depends on the software Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer s product database Planning installation and commissioning of the unit is effected by me...

Page 2: ...98 TSM With illuminated inscription labelling field as an option FIG B Key covers For operation the device must be equipped with the corresponding touch sensor module covers to be ordered separately e g 1 key 3071 or 3091 TSM 1 x FD 901 TSA w labelling field 3091 TSML 1 x FD 902 TSA 2 key 3072 or 3092 TSM 2 x FD 902 TSA w labelling field 3092 TSML 2 x FD 904 TSA 3 key 3073 or 3093 TSM 1 x FD 902 T...

Page 3: ... with illuminated inscription field Fastening with only one plastic screw If possible write the text on the label before fitting 3 1 Montage 1 Fit supporting ring 1 in correct position on a flushmounting box DIN 49073 observe the TOP mark Type A or Typ B in front Use the screws supplied with the mounting box 2 Place decorative frame 2 on the supporting ring 3 Connect the touch sensor module 3 with...

Page 4: ...g the covers press button 7 and hold depressed Then press the button at the lower right 8 9 or 10 The operation LED flashes fast 2 End the programming mode after storing of the physical address by pressing any button 3 Note the physical address on the touch sensor label 4 Load the application software into the device after the physical address has been taken over 4 ...

Page 5: ... Position of the covers see FIG A B When the cover is correctly aligned observe TOP mark on the inside snap it onto the sensor with a brief press Inscription labels Fig F The covers with article nos FD 90x TSA NA can be labelled For labelling commercial grade foils can be printed with the JUNG inscription software and inserted into the keys Fit as shown in FIG F 5 ...

Page 6: ...niform distribution of the illumination light and has a special coating for this purpose 1 If necessary dismantle the touch sensor module byreversing the fitting sequence 2 Pull out the label drawer 3 Place labelled foil into the drawer and slide back I place 4 Technische Daten Medium TP1 KNX Commissioning mode S Mode ETS Power supply 21 32 V DC Connection KNX connecting terminal Power consumption...

Page 7: ...fault ALBRECHT JUNG GMBH CO KG Service Center Kupferstr 17 19 D 44532 Lünen Service Line 49 23 55 80 65 51 Telefax 49 23 55 80 61 65 E Mail mail vka jung de General equipment Service Line 49 23 55 80 65 55 Telefax 49 23 55 80 62 55 E Mail mail vkm jung de KNX equipment Service Line 49 23 55 80 65 56 Telefax 49 23 55 80 62 55 E Mail mail vkm jung de The CE Sign is a free trade sign addressed exclus...

Reviews: