Page 1: ...erface Art No 2131USBSREG USB data interface Art No 2131USBS ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www ju...
Page 2: ...instructions 2 1 5 Device components 2 2 6 Fitting and electrical connection 2 3 7 Commissioning 2 4 9 Technical data 3 11 Software description 4 12 Software specification 4 1 12 Software 4 2 13 Scop...
Page 3: ...ing software from version ETS4 or higher The USB data interface supports KNX long frames from version ETS5 or higher The device electronics are supplied fully via the USB interface of the connected PC...
Page 4: ...Art No 2131USBSREG Art No 2131USBS 1 3 Accessories Centre plate Art No 569 Page 4 of 17 Product definition...
Page 5: ...al devices may only be mounted and connected by electrically skilled persons Serious injuries fire or property damage possible Please read and follow manual fully These instructions are an integral pa...
Page 6: ...face has a type B USB socket There are no controls or indicators on the device Figure 1 Device components RMD Figure 2 Device components FM 1 KNX connection 2 USB connection socket type B 3 Slide for...
Page 7: ...A Lay the USB connecting cable in front of the field cover of the distribution board o Insert the USB plug type B into the connection socket of the USB data interface o Lead the USB connecting cable...
Page 8: ...ting the FM device o Install the device in the appliance box o Fit the frame onto the appliance box o Mount the TAE cover Connecting the FM device Figure 4 Device connection FM design o Make the KNX c...
Page 9: ...stem USB support is possible in current Windows operating systems The device can first be accessed by the ETS after successful installation or activation of the drivers Programming the physical addres...
Page 10: ...2131USBS By leaving the field the physical address is programmed to the USB data interface The newly programmed physical address is displayed under Current interface Page 10 of 17 Mounting electrical...
Page 11: ...C 21 32 V SELV KNX medium TP 256 Protection class II Ambient temperature 5 45 C Storage transport temperature 25 70 C Fitting width Art No 2131USBSREG 36 mm 2 modules Art No 2131USBS USB USB connectio...
Page 12: ...ommunication USB USB data interface Configuration S mode standard No Short description Name Version from mask version 1 No application program is required for this device The physical address is assig...
Page 13: ...4 or higher Support of long frames for the ETS5 The device electronics are supplied fully via the USB interface of the PC The firmware of the device can be updated Thus the device can be adapted to fu...
Page 14: ...general interface settings of the ETS This device has no parameters and objects Thus it is not necessary to program an application program The product database available to the product can be imported...
Page 15: ...m The current firmware version is shown in the name of the product database The firmware update may take some time During this period the device does not send any valid values to the KNX After the fir...
Page 16: ...Index A Application program 14 C Commissioning 9 E ETS search paths 12 H HID Driver 9 I Initialisation 9 M Mounting 7 8 P physical address 9 U USB Driver 9 Art No 2131USBSREG Art No 2131USBS Page 16...