background image

Figure 2: Clampable cable cross-sections

o

Install insert in appliance box, device connection terminals must be at the bottom.

i

Do not attach or replace the cover under voltage, otherwise this might cause a malfunction.

o

Attach the frame and the cover.

o

Switch on mains voltage.

5 Appendix

5.1 Technical data

Rated voltage

AC 230 V ~

Mains frequency

50 / 60 Hz

Ambient temperature

-20 ... +45  °C

Storage/transport temperature

-20 ... +70  °C

Total length of extension unit cable

max. 100 m

5.2 Troubleshooting

Operation via extension does not function properly

Cause: power and extension unit cables are routed in a shared cable. Interferences of the
power cable in the extension unit cable can lead to errors in the telegram transmission. 

Route power and extension unit cables in separate cables.
Decrease current load on the power cable.

5.3 Accessories

Standard centre plate

Art. No. ..1700..

5.4 Warranty

The warranty follows about the specialty store in between the legal framework as provided for
by law.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1
58579 Schalksmühle
GERMANY

Telefon: +49 2355 806-0
Telefax: +49 2355 806-204
[email protected]
www.jung.de

3/3

82598003
J0082598003

22.11.2017

LB Management

Satellite insert 2-wire

Reviews: