Switching the light

Brief press on the operating cover: Light is switched on or off at the last set
brightness/colour temperature or a saved brightness/colour temperature.

Long press on the operating cover at the bottom: Light is switched on at min-
imum brightness.

Adjusting the brightness

Long press on the operating cover at the top or bottom.

Setting the colour temperature

Press the operating cover in the switched-on state at the top, bottom or over
the entire surface twice within 0.4 seconds (double-click). The light switches
off and on again.

Long press on the operating cover at the top or bottom.

After a further double click, the insert switches back to normal operation and
signals this with a short switching off and on again. After one minute without
operation, the insert also returns to normal operation.

With a LB Management push-button 2-gang the right rocker is used to directly
set the colour temperature.

Saving the switch-on brightness / colour temperature

Set the brightness and colour temperature.

Press operating cover over entire surface for longer than 4 seconds.

The light switches off and on again. The brightness and the colour temperat-
ure are saved.

Deleting the switch-on brightness

Press the operating cover briefly: Light switches on at the saved switch-on
brightness and colour temperature.

Press the operating cover for longer than 4 seconds: Switch-on brightness and
colour temperature are deleted.

When switching on, the brightness and colour temperature present prior to
switching off are set now.

Different operation with push-button extension

Long press on the push-button: Adjust the brightness. Push-button: The ad-
justment direction is changed with each new long actuation.

Double-click the push-button: The mode for changing the colour temperature
is called up. The direction of the change in colour temperature changes with
each new long actuation.

After one minute without operation, the insert returns to normal operation.

Power DALI push-button controller TW

4 / 9

82598933

19.08.2022

J0082598933

Summary of Contents for 1713DSTE

Page 1: ...wer DALI push button controller TW Art no 1713DSTE 19 08 2022 82598933 J0082598933 ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de ...

Page 2: ...tents 1 Safety instructions 3 2 Intended use 3 3 Operation 3 4 Information for electrically skilled persons 5 5 Technical data 8 6 Warranty 9 2 9 82598933 19 08 2022 J0082598933 Power DALI push button controller TW ...

Page 3: ...nnot be guaranteed in combination with other DALI controls it is thus not recommend Product characteristics DALI supply for a maximum of 18 DALI subscribers Parallel switching of up to 4 DALI control units with the option of supplying up to 72 DALI subscribers Storing of minimum brightness coldest and warmest colour temperature Switching on with the last set brightness colour temperature or saved ...

Page 4: ...erature Saving the switch on brightness colour temperature Set the brightness and colour temperature Press operating cover over entire surface for longer than 4 seconds The light switches off and on again The brightness and the colour temperat ure are saved Deleting the switch on brightness Press the operating cover briefly Light switches on at the saved switch on brightness and colour temperature...

Page 5: ...or load disengage all the corresponding cir cuit breakers Cover up live parts Connecting and fitting the device Image 1 Connection diagram with optional extensions 1 DALI insert 2 Cover interface with LED 3 Button Test 4 DALI subscriber 5 3 wire extension 6 2 wire extension 7 Push button NO contact Power DALI push button controller TW 5 9 82598933 19 08 2022 J0082598933 ...

Page 6: ...s guaranteed A 3 wire extension can only control one DALI insert Central control is not pos sible on several DALI inserts To increase the detection field of motion or presence detectors up to 10 devices can be connected to the DALI insert via 3 wire extensions The connected DALI subscribers may be operated on different phases The connected lighting can also be switched without a cover by briefly p...

Page 7: ... button Test is not pressed for more than 30 seconds the setting mode is automatically exited the settings are applied and the LED goes out To change the minimum brightness press and hold the button Test for longer than one second The LED flashes green and the luminaire starts to become brighter with min imum brightness Once the desired minimum brightness is reached release the button Test The LED...

Page 8: ...est as soon as a change in the colour temperature is vis ible on the luminaire The LED lights up red the warmest colour temperature is saved To exit the setting mode briefly press the button Test again Resetting the insert to factory settings Precondition Load is switched off Press the Test button for at least 20 seconds The red LED lights up Release the button and press it briefly once again with...

Page 9: ... max 100 m 6 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de Power DALI push button controller TW 9 9 82598933 19 08 2022 J0082598933 ...

Reviews: