Switching the light
■
Brief press on the operating cover: Light is switched on or off at the last set
brightness/colour temperature or a saved brightness/colour temperature.
■
Long press on the operating cover at the bottom: Light is switched on at min-
imum brightness.
Adjusting the brightness
■
Long press on the operating cover at the top or bottom.
Setting the colour temperature
■
Press the operating cover in the switched-on state at the top, bottom or over
the entire surface twice within 0.4 seconds (double-click). The light switches
off and on again.
■
Long press on the operating cover at the top or bottom.
After a further double click, the insert switches back to normal operation and
signals this with a short switching off and on again. After one minute without
operation, the insert also returns to normal operation.
With a LB Management push-button 2-gang the right rocker is used to directly
set the colour temperature.
Saving the switch-on brightness / colour temperature
■
Set the brightness and colour temperature.
■
Press operating cover over entire surface for longer than 4 seconds.
The light switches off and on again. The brightness and the colour temperat-
ure are saved.
Deleting the switch-on brightness
■
Press the operating cover briefly: Light switches on at the saved switch-on
brightness and colour temperature.
■
Press the operating cover for longer than 4 seconds: Switch-on brightness and
colour temperature are deleted.
When switching on, the brightness and colour temperature present prior to
switching off are set now.
Different operation with push-button extension
■
Long press on the push-button: Adjust the brightness. Push-button: The ad-
justment direction is changed with each new long actuation.
■
Double-click the push-button: The mode for changing the colour temperature
is called up. The direction of the change in colour temperature changes with
each new long actuation.
After one minute without operation, the insert returns to normal operation.
Power DALI push-button controller TW
4 / 9
82598933
19.08.2022
J0082598933