Light Management

 

 

Tronic switching insert 
Ref.-no.:1254TSE 

 

 
Depending upon the type of installation, the maximum connected load 
must be reduced by: 

- 6.5 % per 5 °C exceeding of the ambient temperature of 25°C. 
- 15% for installation in wooden, gypsum plaster or hollow walls. 
- 20% for installation in multiple combinations. 

Note the technical connection conditions of the power stations.  

7.  The Use of Extensions 

Connect several extensions as shown in Fig. C. 

 

Fig. C 

Connect several extensions as shown in Fig. C. 
Control from an extension unit is possible only if the attachment on the 
main unit is in place. 
Tronic switching insert 

g

 

"2-wire" extension insert 

h

 

Connection of further extensions 

i

 

Load 

j

 

"2-wire" extension insert:  

Using the short-stroke key leads to 
the same functionality as on the 
Tronic switching insert. 

Mechanical push-button (n. o. contact): ON/OFF (toggling) 
Illuminated mechanical pushbuttons must have a separate N terminal. 

8. Technical 

specifications 

Nominal voltage:  

AC 230 V ~, 50 / 60 Hz 

Operating temperature:  

-20 °C ... +45 °C 

Connected load:  

50 - 420 W/VA 

 

- Incandescent lamps 

 

- HV halogen lamps 

 

- Tronic transformers 

Number of Extensions: 
"2-wire" extension insert, 
mechanical push-button:  

unlimited 

"3-wire" extension insert:  

10 

Different types of extension units can be combined 

Total length of extension connecting cable:  

max. 100 m 

 