Jung 1240 STE Operating Instructions Manual Download Page 2

 

Light Management

 

Pushbutton control unit 
Ref.-no.: 1240 STE  
R3 

 

Operation when the device is on: 

Brief depression (less than 400 ms): 

UPPER pushbutton or LOWER pushbutton or both: OFF. 

Long depression (longer than 400 ms): 

UPPER pushbutton: increasing the brightness up to maximum. 
LOWER pushbutton: reducing the brightness down to minimum. 

Both pushbutton faces (at least 3 seconds):  

The current brightness level is stored in an NV memory and recalled 
when the device is switched on again (brief press). Storage is confirmed 
by cutting out the lamp for 1 second and by subsequent restarting with 
the stored brightness value. 

 

Storing a memory value 

When an automatic-switch ‘Universal’ is used, a memory value can be 
saved via an extension. The saving procedure is described at length in 
the operating instructions of the attachment. 
 

Adjustment of basic brightness 

Important: 

When using the multifunction pushbutton ‘Universal’ as a time 

switch, the basic brightness is stored only in the pushbutton.

 

The basic brightness value is saved in a non-volatile memory. The 
adjustment as such can only be made directly on the pushbutton control 
unit itself. For storing, press the center of the button (not multifunction 
pushbutton with radio-control receiver and multifunction pushbutton 
‘Universal’) for at least 20 seconds when off. The lights are at first set to 
maximum brightness. After ca. 20 seconds, the device switches to 50% 
brightness to confirm that it is ready for programming. Now dim the lights 
until the desired basic brightness is reached. Release the key. After ca. 
20 seconds, the basic brightness is saved and the load switched off for 
confirmation. If the basic brightness is to be stored during operation of the 
pushbutton control unit with a presence detector, an automatic switch, a 
multifunction pushbutton or a multifunction pushbutton with radio-control 
receiver, proceed as follows: 
 

Attention: Observe the safety warnings. 

1.  Disconnect the mains voltage. 

2.  Withdraw the presence detector, automatic switch, 

multifunction pushbutton or multifunction pushbutton with 
radio-control receiver from the insert. 

3.  Plug a pushbutton on the insert. 

4.  Switch on the mains supply. 

5.  Adjust the basic brightness (see above). 

6.  Disconnect the mains voltage. 

7.  Withdraw the pushbutton from the insert. 

8.  Plug the presence detector, automatic switch, multifunction 

pushbutton or multifunction pushbutton with radio-control 
receiver on the insert. 

9.  Switch on the mains voltage. 

 

Summary of Contents for 1240 STE

Page 1: ...ic ballasts or TRONIC transformers with 1 10V interface Switching and dimming commands are given by actuating the attachments for the pushbutton control units extension units or radio control transmit...

Page 2: ...itself For storing press the center of the button not multifunction pushbutton with radio control receiver and multifunction pushbutton Universal for at least 20 seconds when off The lights are at fi...

Page 3: ...ation the max load connected must be reduced 10 for every 5 C above the ambient temperature of 25 C 15 for installations in wooden gypsum plasterboard or hollow walls 20 for installations in multi dev...

Page 4: ...1240 STE R3 1 pushbutton control unit 5 load 6 switched phase to other loads 7 1 10 V control lines to other loads 8 2 wire extension unit art no 1220 NE 9 3 wire extension insert art no 1223 NE 10 m...

Page 5: ...Functions available only if an automatic switch or a presence detector attachment is used also on the main unit Extension unit 2 wire with short stroke key Same functions as with the pushbutton contr...

Page 6: ...rt is connected as shown in fig C The number of electronic ballasts or TRONIC transformers that can be dimmed with a single pushbutton control unit depends on the control current of the individual ele...

Page 7: ...ns potential Total length of cable to extension units max 100 m 7 Guarantee Our products are under guarantee within the scope of the statutory provisions Please return the unit postage paid to our cen...

Reviews: