background image

6

Stock and transport

Stock environment:temperature   5

--45

      

Humidity        9%--45%

The product can be sent by air ,sea and land-carriage,but can’t place it 
in the open air.

Cleaning

Mainframe:use the litmusless cleanser or alcohol to clean the surface,don’t

let the liquid get into the inside of the device,especially the LCD display 

windows. 

Probe:use the litmusless cleanser or alcohol to clean the surface,the line and

sheath can use the litmusless cleaser to clean it.

Safety sort

The safety sort of the product is :II Before

Apply  range

Suit for fetus more than 16 weeks old

Summary of Contents for JPD-100A

Page 1: ...JPD 100A JPD 100A Fetal doppler OPERATE MANUAL Jumper Medical Co Ltd...

Page 2: ...umper Medical Co Ltd our company can reserve all the copyright of expert puissance according to the legality With out the company script permission no one is allowed to increase and decrease brief pir...

Page 3: ...tice caution and suggestive instruction 2 Specification 2 Main configuration 3 Function keys introduction 4 Operate manual 5 Stock and transport 6 Cleaning 6 Safety sort 6 Apply range 6 In case of dif...

Page 4: ...ase offer the model number S N date of buying and contact information when you contact us Standard packing list 1 mainframe including Probe 1 set 2 adapter 1 pc 3 Specification 1 pc 4 Warranty card 1...

Page 5: ...u can use the litmusless cleanser to clean the surface do not put it in high temperature or use corrosive cleanser you can use a few of alcohol to clean the probe 3 When you finish using it use the cl...

Page 6: ...tart and stop button Monitor mode switch button Loudhailer hole 3 Charge junction 10 10 11 11 12 12 11 11 12 12 Battery storehouse Label Back of the mainframe Head on of the mainframe 10 10 Insert fro...

Page 7: ...itor model when you turn on the equipment acquiescence model 1 Turn down button press it the volume reduced until no voice when the volume is minimum press it will without voice Turn up button press i...

Page 8: ...seless and without voice 4 Turn off When you do not use it press for 2 seconds to turn off it The equipment will auto turn off if it is no signal press to restart it Handmade measure HR 1 Turn on the...

Page 9: ...the litmusless cleanser or alcohol to clean the surface don t let the liquid get into the inside of the device especially the LCD display windows Probe use the litmusless cleanser or alcohol to clean...

Page 10: ...ur dealer or service representative Symptom Cause Remedy Audio scream Weak sound output Low sensitivity Change the battery Turn down the volume Use less Gel Turn up the volume Add Gel Change the batte...

Page 11: ...circuit diagram circuit diagram 8...

Page 12: ...Manufacturer Jumper Medical Co Limited Address 2nd floor Number 5 Building Number 5 Industry Village Number 5 Industry Road Shenzhen Tel 86 755 83547883 Zip Code 518067 Website www jumper med com...

Reviews: