83
1) Press
3
in the copy pop-up screen and the deletion pop-up screen to display the deletion pop-up
screen.
2) Select the pattern No. you desire to delete in the deletion pop-up screen.
7
: Select the pattern to be deleted with “+” and “–”.
When
is pressed here, the screen returns to the former one without deleting.
3) When
is pressed, deletion is performed.
Condensation custom can perform condensation by specifying free needle entry position.
Condensation custom patterns can be created up to as many as 64 steps. As many as 20 patterns can be
registered at the sewing start and the sewing end respectively.
(1) Condensation custom setting
■
Reverse feed stitching setting (condensation custom) screen
6-11. Condensation Custom
1) Press
to display the reverse feed stitching setting screen.
2) Select the shape of condensation in the reverse feed stitching screen.
1
: Select the shape of condensation at sewing start from among 1 to 20.
Standard condensation
, 2-point-condensation
and condensation customs
to
are
changed over and displayed in the display section.
4
: Select the shape of condensation at sewing end from among 1 to 20.
Standard condensation
, 2-point condensation
and condensation customs
to
are
changed over and displayed in the display section.
2
,
5
: Needle entry position is displayed when selecting the condensation custom.
3
,
6
: Total display and partial display of the condensation custom pattern are changed over.
Standard delivery level of the key lock is “1”. When the level of the key lock is the case
other than “0”, be sure to change the level to “0” to perform the operation below.
Impor tant
When the number of registered pieces is one, deletion cannot be performed. When you
desire to delete it, perform deletion after creating another No.
The custom pattern registered in the pattern cannot be deleted.
Once the data is deleted, it does not return to the former one. Be sure to press
after
carefully checking the data.
Cau tion
Reference
4
1
1
4
2
5
3
6