a
A
19
1
2
0.05~0.1 mm
The tip of hook
Needle
5-12 Distance-needle-hook
- Choose patterns
, zigzag 7 mm.
-
Remove face plate and needle plate.
-
Take off the shuttle hook.
-
Set the needle towards the lowest point
of right side and lift it, make sure if space
between needle and the tip of the shuttle
hook holder should be 0.05~0.1mm. (1)
-
If the space is incorrect:
Loosen the screw (a) of the needle bar
supporter.
Push the needle bar supporter (A)
backward (
), and the space will
become larger.
Push the needle bar supporter toward
(
), and the space will become smaller.
(2)
backward
forward