− 78 −
2-16. Memory switch data list
No.
Item
Setting range
Edit unit
Initial value
U01
Presser lifter maximum position
Heght of maxmum poston of pedal opera-
ton s set.
0 to 17.0
0.1mm
14.0mm
U02
Presser lifter intermediate position
Heght of ntermedate poston of pedal op-
eraton s set.
0 to 14.0
0.1mm
6.0mm
U03
Presser lifter cloth setting position
Heght of cloth settng poston of pedal op-
eraton s set.
0 to 14.0
0.1mm
0.0mm
U06
Needle thread tension at sewing end set
-
ting
0 to 200
1
35
U07
Needle thread tension at thread trimming
setting
0 to 200
1
35
U08
Needle thread tension of basting for sew
-
ing together setting
0 to 200
1
60
U09
Soft-start speed setting 1st stitch
400 to 4200
100st/mn
800st/mn
U10
Soft-start speed setting 2nd stitch
400 to 4200
100st/mn
800st/mn
U11
Soft-start speed setting 3rd stitch
400 to 4200
100st/mn
2000st/mn
U12
Soft-start speed setting 4th stitch
400 to 4200
100st/mn
3000st/mn
U13
Soft-start speed setting 5th stitch
400 to 4200
100st/mn
4000st/mn
U14
Kind of presser
-
-
Type 1
U15
Presser size width
When type 5 of U14 Knd of presser s set,
nput the wdth of the presser.
3.0 to 10.0
0.1mm
3.0mm
U16
Presser size length
When type 5 of U14 Knd of presser s set,
nput the length of the presser.
10.0 to 120.0
0.5mm
10.0mm
U17
Sewing start position (Feed direction)
Sewng start poston n terms of presser s set.
Set ths tem when startng poston s desred
to be shfted due to overlapped secton or the lke.
2.5 to 110.0
0.1mm
2.5mm
U18
Cloth cutting knife size
Input knfe sze used.
3.0 to 32.0
0.1mm
32.0mm
U19
Function of plural motions of cloth cutting knife
Ineffective/effective
: Ineffective
: Effective
-
-
Ineffectve
U20
Function of thread breakage detection Ineffective/ef
-
fective
: Ineffective
: Effective
-
-
Effectve
(1) Level 1
☆
Memory swtch data (level 1) are the moton data that the sewng machne has n common and the
data that operate on all sewng patterns n common.