 the foundation of the Hybrid AC Filter design which conditions in-
coming AC power, removing normal and common mode noise without 
adversely affecting the ground line. 

 

 

 
 
 

 
 
 
 

 
 

 

TROUBLESHOOTING 

The RX100 is ruggedly designed and constructed from high quality 

components to give years of dependable power for your equipment. 
It requires neither maintenance nor adjustment. It is unlikely to mal-
function. However, there is one potential event to note: 
 
The RX100 will not come on or turns itself off. 

 

a. Check the status of the power supplied to the unit. If line 

voltage exceeds 165 volts for 3 seconds protection circuitry will dis-
connect power to the AC power outputs. This will also occur if the 
line and neutral leads are reversed or if there is no ground connec-
tion. Use a voltage meter and/or polarity tester to examine the 

status of incoming power. 
 

b. Check that the circuit breaker is not tripped and that the 

current load on the unit does not exceed its rated 15 amp or 20 amp 
capacity. If the breaker is tripped, remove sufficient current load to 

reduce the total to no more than 15 amps or 20 amps (depending on 
the RX100 model). Wait approximately 30 seconds after the tripping. 
Turn off the main power switch and push in the circuit breaker but-
ton. 
If an observed problem can not be remedied, particularly if the prob-

lem seems severe or dangerous, discontinue use of the RX100 and 
contact Juice Goose directly.  

 

REPAIR 

Should your RX100 need service contact Juice Goose for assistance 
and authorization to return the unit. PLEASE NOTE: a return au-
thorization number is required in order for the service personnel to 
correctly and promptly identify, repair and return your unit. You may 