Power Cord
– The power cord has a third pin safety ground connector. Do not
defeat this feature. Doing so could subject user to a hazardous condition.
INTERNAL PROTECTION COMPONENTS
The JG 8 Series products have a basic level of AC power protection consisting
of a fast acting metal oxide varistor between hot and neutral and a line capacitor
between hot and neutral to reduce high frequency line noise and AC line
surges.
TROUBLE SHOOTING
The JG 8 is well designed and constructed. Every JG 8 is submitted to a full
functional test before being shipped by Juice Goose. It requires neither mainte-
nance nor adjustment. It is unlikely to malfunction. However, there are potential
events to note:
The JG 8 will not come on or turns itself off.
a
. Check the status of the power supplied to the unit. Use a voltage meter and/
or polarity tester to examine the status of incoming power.
b
. Check that the circuit breaker is not tripped and that the current load on the
unit does not exceed its rated capacity. If the breaker is tripped, turn off the
power switch, remove sufficient current load to reduce the total to no more than
the rated current capacity, wait approximately 30 seconds after the tripping. Re-
set the circuit breaker and turn the power switch back on.
One or more lights will not turn on.
The incandescent bulbs in the JG 8L and JG 8LM have a long but limited ser-
vice life. Especially if only one of those lights does not function unplug the JG
unit, unscrew the cap on the end of the light tube, examine the bulb and replace
as necessary with a 7 watt candelabra based bulb. The lights on the JG 8LED
should last for the service life of the JG unit. If one of those lights does not work
contact Juice Goose for service assistance and possibly factory repair.
NOTE: If necessary, in order to turn off the JG 8, the power cord to the JG 8
can be unplugged from the wall or other power source.
If an observed problem can not be remedied, particularly if the problem seems
severe or dangerous, discontinue use of the JG 8 and contact Juice Goose di-
rectly.
REPAIR
Should your product need service contact Juice Goose for assistance and au-
thorization to return the unit. PLEASE NOTE: a return authorization number is
required in order for the service personnel to correctly and promptly identify,
repair and return your unit.
You may obtain a Return Authorization Number by calling: 713-772-1404 or
sending email to [email protected].